首页> 外文期刊>Analytical chemistry >Hard Cap Espresso Machines in Analytical Chemistry: What Else?
【24h】

Hard Cap Espresso Machines in Analytical Chemistry: What Else?

机译:分析化学中的硬帽浓缩咖啡机:还有什么?

获取原文
获取原文并翻译 | 示例
       

摘要

A hard cap espresso machine has been used in combination with liquid chromatography with molecular fluorescence detection for the determination of polycyclic aromatic hydrocarbons (PAHs) from contaminated soils and sediments providing appropriate extraction efficiencies and quantitative results. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benz[b]fluoranthene, benz[k]fluoranthene, benz[a]pyrene, dibenz[a,h]anthracene, benz[ghi]perylene, and indeno[1,2,3-cd]pyrene were used as target compounds. It should be mentioned that the pairs benz[a]anthracene-chrysene and dibenz[a,h]anthracene-benz[ghi]perylene peaks coelute under the employed chromatographic conditions; thus, those compounds were determined together. PAHs were extracted from 5.0 g of soil, previously homogenized, freeze-dried, and sieved to 250 mu m, with 50 mL of 40% (v/v) acetonitrile in water at a temperature of 72 +/- 3 degrees C. The proposed procedure is really fast, with an extraction time of 11 s, and it reduces the required amount of organic solvent to do the sample preparation. The obtained limit of detection for the evaluated PAHs was from 1 to 38 mu g kg(-1). Recoveries were calculated using 1000, and 2000 mu g kg(-1) PAHs with values ranging from 81 to 121% and good precision with relative standard deviation values lower than 30%. The method was validated using soil and sediment certified reference materials and also using real samples by comparison with ultrasound-assisted extraction, as reference methodology, obtaining statistically comparable results. Thus, the use of hard cap espresso machines in the analytical laboratories offers tremendous possibilities as low cost extraction units for the extraction of solid samples.
机译:硬帽浓缩咖啡机已与液相色谱和分子荧光检测结合使用,用于测定污染土壤和沉积物中的多环芳烃(PAHs),从而提供适当的萃取效率和定量结果。萘,,芴,菲,蒽,荧蒽,pyr,苯并[a]蒽,,苯并[b]荧蒽,苯并[k]荧蒽,苯并[a] py,苯并[a,h]蒽,苯并[b] hi和茚并[1,2,3-cd] py用作目标化合物。应该提到的是,在所使用的色谱条件下,苯并[a]蒽-蒽和苯并[a,h]蒽-苯并g峰对共洗脱。因此,这些化合物是一起确定的。从5.0 g的土壤中提取PAHs,事先将其均质,冷冻干燥并用50 mL的40%(v / v)乙腈水溶液在72 +/- 3摄氏度的温度下筛分至250微米。所建议的过程确实非常快,提取时间为11 s,并且减少了进行样品制备所需的有机溶剂量。所评估的PAHs的检出限为1至38μg kg(-1)。使用1000和2000μg kg(-1)PAHs计算回收率,其PAHs值在81%到121%之间,精度很高,相对标准偏差值低于30%。该方法已使用土壤和沉​​积物认证的参考材料进行了验证,并且还通过与超声辅助提取进行比较的真实样品(作为参考方法)进行了验证,从而获得了统计上可比的结果。因此,在分析实验室中使用硬帽浓缩咖啡机提供了巨大的可能性,因为它是用于提取固体样品的低成本提取装置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号