首页> 外文期刊>Analytical chemistry >Direct High-Precision Measurements of the Sr-87/Sr-86 Isotope Ratio in Natural Water without Chemical Separation Using Thermal Ionization Mass Spectrometry Equipped with 10(12) Omega Resistors
【24h】

Direct High-Precision Measurements of the Sr-87/Sr-86 Isotope Ratio in Natural Water without Chemical Separation Using Thermal Ionization Mass Spectrometry Equipped with 10(12) Omega Resistors

机译:配备10(12)Omega电阻器的热电离质谱法无需化学分离即可直接高精度测量天然水中Sr-87 / Sr-86同位素比

获取原文
获取原文并翻译 | 示例
           

摘要

Thermal ionization mass spectromety (TIMS) allows excellent precision for determining Sr isotope ratios in natural water samples. Traditionally, a chemical separation procedure using cation exchange resin has been employed to obtain a high purity Sr fraction from natural water, which makes sample preparation time-consuming. In this study, we present a. rapid and precise method for the direct determination of the Sr isotope ratio of natural water using TIMS equipped with amplifiers With two 10(12) Omega resistors. To eliminate the Rb-87 isobaric interference, Re ribbons are used as filaments, providing a significant advantage over W ribbons in the inhibition of Rb+ emission, based on systematically examining a series of NEST SRM987 standard doping with various amounts of Rb using Re and W ribbons. To validate the applicability of our method, twenty-two natural water samples, including different water types (rain, snow, river, lake and drinking water), that show a large range in Sr content variations (2.54-922.8 ppb), were collected and analyzed from North and South China. Analytical results show good precision (0.003-0.005%, 2 RSE) and the method was further validated by comparative analysis of the same water with and without chemical separation. The method is sample and rapid, eliminates sample preparation time, and prevents potential contamination during complicated sample-preparation procedures. Therefore, a high sample throughput inherent to the TINTS can be fully utilized.
机译:热电离质谱(TIMS)可以确保测定天然水样品中Sr同位素比的出色精度。传统上,已经采用了使用阳离子交换树脂的化学分离程序来从天然水中获得高纯度的Sr馏分,这使得样品制备非常耗时。在这项研究中,我们提出一个。使用配备有两个10(12)Omega电阻器的放大器的TIMS,可以直接,快速,准确地确定天然水的Sr同位素比。为了消除Rb-87等压线干扰,Re色带用作灯丝,在系统地检查一系列使用Re和W掺杂各种Rb的NEST SRM987标准掺杂后,Re色带在Wb色带的抑制Rb +发射方面具有显着优势。丝带。为了验证我们方法的适用性,收集了22种天然水样品,其中包括不同的水类型(雨水,雪,河水,湖泊和饮用水),这些样品的Sr含量变化范围很大(2.54-922.8 ppb)。并从华北和华南进行了分析。分析结果表明,该方法具有良好的精密度(0.003-0.005%,2 RSE),并且通过对有或没有化学分离的相同水进行对比分析进一步验证了该方法。该方法样品快速,消除了样品制备时间,并防止了复杂的样品制备过程中的潜在污染。因此,可以充分利用TINTS固有的高样品通量。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号