A peptidyl fluorescent chemosensor for heparin was synthesized by conjugating a pyrene fluorophore with the heparin-binding peptide. The fluorescent chemosensor (Py12; pyrene-RKRLQVQLSIRT) showed a highly sensitive ratiometric response to nanomolar concentrations of heparin in aqueous solutions at physiological pH by increasing excimer emission intensity at 500 nm with a concomitant decrease in monomer emission intensity at 400 nm. Py12 showed a sensitive ratiometric response to heparin over a wide pH range (1.5 ≤ pH ≤ 11.5) and exhibited high selectivity for heparin compared to other biological competitors, such as hyaluronic acid and chondroitin sulfate. Py12 sensitively and ratiometrically detected nanomolar concentrations of heparin in biologically relevant samples containing human serum and human plasma, respectively. The detection limit of Py12 was 34 pM (R~2 = 0.997) for heparin in an aqueous buffer solutions containing 5% human serum and 33 pM (R~2 = 0.994) for heparin in aqueous buffer solutions containing 5% human plasma. Py12 had sufficient sensitivity and selectivity for ratiometrically detecting a nanomolar concentration of heparin, indicating that the peptide-base chemosensor provides a potential tool for monitoring heparin levels in clinical plasma samples.
机译:通过将a荧光团与肝素结合肽缀合来合成用于肝素的肽基荧光化学传感器。荧光化学传感器(Py12; pyr-RKRLQVQLSIRT)在生理pH值下,通过增加500 nm的准分子发射强度,同时在400 nm处的单体发射强度降低,显示出对水溶液中纳摩尔浓度肝素的纳摩尔浓度的高灵敏度比率响应。与其他生物竞争对手(如透明质酸和硫酸软骨素)相比,Py12在较宽的pH范围(1.5≤pH≤11.5)中对肝素表现出敏感的比例响应,并且对肝素具有高选择性。 Py12敏感地和按比例地检测到含有人血清和人血浆的生物学相关样品中肝素的纳摩尔浓度。在含有5%人血清的缓冲水溶液中,肝素的Py12检测限为34 pM(R〜2 = 0.997),而在含有5%人血浆的缓冲水溶液中,肝素的Py12检测限为33 pM(R〜2 = 0.994)。 Py12具有足够的灵敏度和选择性,可以按比例检测肝素的纳摩尔浓度,这表明基于肽的化学传感器为监测临床血浆样品中的肝素水平提供了一种潜在的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号