首页> 外文期刊>Analytical chemistry >Integrated Capillary Zone Electrophoresis-Electrospray Ionization Tandem Mass Spectrometry System with an Immobilized Trypsin Microreactor for Online Digestion and Analysis of Picogram Amounts of RAW 264.7 Cell Lysate
【24h】

Integrated Capillary Zone Electrophoresis-Electrospray Ionization Tandem Mass Spectrometry System with an Immobilized Trypsin Microreactor for Online Digestion and Analysis of Picogram Amounts of RAW 264.7 Cell Lysate

机译:固定化胰蛋白酶微反应器的集成毛细管区带电泳-电喷雾串联质谱系统用于在线消化和分析RAW 264.7细胞裂解液的皮克数量

获取原文
获取原文并翻译 | 示例
           

摘要

A capillary zone electrophoresis (CZE) electrospray ionization (ESI) tandem mass spectrometry (MS/MS) system was integrated with an immobilized trypsin microreactor. The system was evaluated and then applied for online digestion and analysis of picogram loadings of RAW 264.7 cell lysate. Protein samples were dissolved in a buffer containing 50% (v/v) acetonitrile (ACN), and then directly loaded into the capillary for digestion, followed by CZE separation and MS/MS identification. The organic solvent (50% (v/v) ACN) assisted the immobilized trypsin digestion and simplified the protein sample preparation protocol. Neither protein reduction nor alkylation steps were employed, which minimized sample loss and contamination. The integrated CZE-ESI-MS/MS system generated confident identification of bovine serum albumin (BSA) with 19% sequence coverage and 14 peptide identifications (IDs) when 20 fmol was loaded. When only 1 fmol of BSA was injected, one BSA peptide was consistently detected. For the analysis of a standard protein mixture, the integrated system produced efficient protein digestion and confident identification for proteins with different molecular weights and isoelectric points when a low-femtomole amount was loaded for each protein. We further applied the system for triplicate analysis of a RAW 264.7 cell lysate; 2 ± 1 and 7 ± 2 protein groups were confidently identified from only 300 pg and 3 ng loadings, respectively. The 300 pg sample loading corresponds to the protein content of three RAW 264.7 cells. In addition to high-sensitivity analysis, the integrated CZE-ESI-MS/MS system produces good reproducibility in terms of peptide and protein IDs, peptide migration time, and peptide intensity.
机译:毛细管区带电泳(CZE)电喷雾电离(ESI)串联质谱(MS / MS)系统与固定化的胰蛋白酶微反应器集成在一起。对该系统进行了评估,然后用于在线消化和分析RAW 264.7细胞裂解物的皮克含量。将蛋白质样品溶解在含有50%(v / v)乙腈(ACN)的缓冲液中,然后直接加载到毛细管中进行消化,然后进行CZE分离和MS / MS鉴定。有机溶剂(50%(v / v)ACN)有助于固定化胰蛋白酶的消化并简化了蛋白质样品的制备流程。既不使用蛋白质还原步骤也不进行烷基化步骤,从而最大程度减少了样品损失和污染。当装载20 fmol时,集成的CZE-ESI-MS / MS系统产生了具有19%序列覆盖率和14个肽段识别符(ID)的牛血清白蛋白(BSA)可信度鉴定。当仅注射1 fmol BSA时,始终检测到一种BSA肽。对于标准蛋白质混合物的分析,当为每种蛋白质加载低飞摩尔量时,该集成系统可对不同分子量和等电点的蛋白质进行有效的蛋白质消化和确定性鉴定。我们进一步将该系统应用于RAW 264.7细胞裂解液的三次分析。分别仅从300 pg和3 ng的加载量中可靠地鉴定出2±1和7±2个蛋白质组。 300 pg样品上样量对应于三个RAW 264.7细胞的蛋白质含量。除高灵敏度分析外,集成的CZE-ESI-MS / MS系统在肽和蛋白质ID,肽迁移时间和肽强度方面均具有良好的重现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号