首页> 外文期刊>Analytical chemistry >Impact of Peptide Modifications on the Isobaric Tags for Relative and Absolute Quantitation Method Accuracy
【24h】

Impact of Peptide Modifications on the Isobaric Tags for Relative and Absolute Quantitation Method Accuracy

机译:肽修饰对等压标记的影响,相对和绝对定量方法的准确性

获取原文
获取原文并翻译 | 示例
       

摘要

In this study, the impact of amino acid modifications on the accuracy of the iTRAQ (isobaric tags for relative and absolute quantitation) method was evaluated. MCF-7 breast cancer cells, cultured in the presence of 17beta-estradiol and tamoxifen, were used as a model system. The cells were labeled and analyzed by reversed-phase liquid chromatography and pulsed Q dissociation ion trap tandem mass spectrometry detection. Database searching was performed by using various combinations of amino acid modification allowances, i.e, Lys/Tyr/Cys and amino terminal iTRAQ labeling, Lys methylation, acetylation and carbamylation, and Cys/Met oxidation. Other than the intended Lys/amino terminal iTRAQ labeling, such modifications occur as a result of either enzymatic or sample preparation related reactions and are typically ignored in quantitation analysis to minimize the rate of false-positive peptide identifications. The study revealed that the modifications with the greatest impact on protein identification and quantitation pertain to Lys and Tyr amino acid residues, that by enabling such modifications the number and type of identified proteins will change (by up to 10percent), and that the rate of false-positive protein identifications can be maintained below an upper threshold of 5percent if appropriate data filtering conditions are used. In addition, the interference of possible posttranslational modifications (i.e., phosphorylation) with iTRAQ quantitation was examined.
机译:在这项研究中,评估了氨基酸修饰对iTRAQ(等压标记用于相对和绝对定量)方法准确性的影响。将在17β-雌二醇和他莫昔芬存在下培养的MCF-7乳腺癌细胞用作模型系统。标记细胞并通过反相液相色谱和脉冲Q解离离子阱串联质谱检测法进行分析。通过使用氨基酸修饰余量的各种组合进行数据库搜索,即Lys / Tyr / Cys和氨基末端iTRAQ标记,Lys甲基化,乙酰化和氨基甲酰化以及Cys / Met氧化。除了预期的Lys /氨基末端iTRAQ标记外,此类修饰是酶或样品制备相关反应的结果,通常在定量分析中被忽略,以最大程度地降低假阳性肽的鉴定率。该研究表明,对蛋白质鉴定和定量影响最大的修饰涉及Lys和Tyr氨基酸残基,通过启用此类修饰,鉴定出的蛋白质的数量和类型将发生变化(最多10%),并且如果使用适当的数据过滤条件,则可以将假阳性蛋白质鉴定值保持在5%的上限以下。此外,还检查了iTRAQ定量分析可能对翻译后修饰(即磷酸化)的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号