The existence of surfactants in proteomics samples can severely reduce enzymatic digestion efficiency, liquid chromatography (LC) separation efficiency, column lifetime, and mass spectrometry (MS) sensitivity. Although various techniques are able to remove surfactants, surfactants may occasionally be retained in samples due to variations in sample preparation method or personal skill. Evaluation of surfactant residue in a sample, however, usually requires an additional instrument and is time-consuming. In this study, a simple and rapid visual indicator for surfactant abundance (VISA) was developed. With the detection of a visible surfactant pellet in the solution, this assay was able to detect surfactant residue in aqueous solutions within 5 min. Without the need of additional equipment such as a mass spectrometer, every user can perform a quick test on their bench before sending the sample to the MS facility. The detection limit for the commonly used surfactants, Triton X-114 and SDS, was about 0.0005percent and 0.0002percent, respectively. The VISA was successfully applied to evaluate the efficiency of removal of surfactants in Triton X-114 extracted membrane proteins using tube-gel. With the combination of Triton X-114 extraction and tube-gel protocol, a study of spermatozoa membrane proteome identified about 252 proteins of which about 67.5percent were classified as membrane proteins. The coexistence of protein and surfactant did not affect the VISA sensitivity, suggesting that this indicator is suitable for proteomics applications. The VISA also has potential for the detection of other surfactants and can be applied to other surfactant removing protocols.
机译:蛋白质组学样品中表面活性剂的存在会严重降低酶消化效率,液相色谱(LC)分离效率,色谱柱寿命和质谱(MS)灵敏度。尽管各种技术都能去除表面活性剂,但由于样品制备方法或个人技能的差异,表面活性剂有时仍会保留在样品中。但是,样品中表面活性剂残留的评估通常需要额外的仪器,并且很耗时。在这项研究中,开发了一种简单快速的表面活性剂丰度视觉指示器(VISA)。通过检测溶液中可见的表面活性剂沉淀,该测定法能够在5分钟内检测水溶液中的表面活性剂残留。无需其他设备(例如质谱仪),每个用户都可以在将样品发送到MS设备之前在工作台上进行快速测试。常用的表面活性剂Triton X-114和SDS的检出限分别约为0.0005%和0.0002%。 VISA已成功应用于评估使用管凝胶去除Triton X-114提取的膜蛋白中表面活性剂的效率。通过结合Triton X-114提取和管凝胶实验,对精子膜蛋白质组的研究鉴定出约252种蛋白质,其中约67.5%被归类为膜蛋白质。蛋白质和表面活性剂的共存并不影响VISA敏感性,这表明该指标适用于蛋白质组学应用。 VISA还具有检测其他表面活性剂的潜力,可以应用于其他去除表面活性剂的方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号