The tetraether index of tetraethers consisting of 86 carbons (TEX_(86)) is a novel proxy applied to obtain paleotemperature reconstructions from marine and lacustrine settings. It is usually applied alongside the branched vs isoprenoid tetraether (BIT) index, which provides paleoenvironmental information as well as information on the reliability of TEX_(86). Both indices are calculated via the analysis of glycerol dialkyl glycerol tetraethers or GDGTs by means of high-performance liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (HPLC/APCI-MS). Here we test the performance of alternative methods for sample cleanup and instrumental analysis. In particular, we evaluate using alkaline hydrolysis as an alternative cleanup step to alumina column fractionation and show that the resulting TEX_(86) and BIT are statistically equivalent. We also test two different adsorbents in the activated or deactivated state for preparative column fractionation and show that any of them can be used to measure TEX_(86) but that a certain discrimination between GDGTs used in the BIT index can occur. Regarding the mass spectrometer design, an ion-trap is shown to be as precise as a quadrupole mass spectrometer for GDGT analysis. Some differences are observed for TEX_(86) and especially for BIT values obtained from both MS designs. We provide evidence that the APCI conditions are at least partly responsible for these differences. We recommend caution when comparing BIT values among laboratories as this index seems to be especially sensitive to analytical conditions.
机译:由86个碳组成的四醚的四醚指数(TEX_(86))是一种新颖的代理产品,可用于从海洋和湖泊环境中获得古温度重构。它通常与支链vs类异戊二烯四醚(BIT)指数一起使用,该指数提供了古环境信息以及TEX_(86)的可靠性信息。通过高效液相色谱/大气压化学电离质谱(HPLC / APCI-MS)对甘油二烷基甘油四醚或GDGT的分析来计算两个指数。在这里,我们测试了用于样品净化和仪器分析的替代方法的性能。特别是,我们评估了使用碱水解作为氧化铝柱分级分离的替代纯化步骤,并证明了所得TEX_(86)和BIT在统计上是等效的。我们还测试了两种不同的吸附剂在活化或失活状态下的制备柱分离效果,结果表明它们中的任何一种均可用于测量TEX_(86),但在BIT指数中使用的GDGT之间可能存在一定的区别。关于质谱仪的设计,离子阱被证明与用于GDGT分析的四极质谱仪一样精确。对于TEX_(86),尤其是从两种MS设计获得的BIT值,观察到一些差异。我们提供的证据表明,APCI条件至少部分是造成这些差异的原因。我们建议在比较实验室之间的BIT值时要谨慎,因为该指数似乎对分析条件特别敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号