首页> 外文期刊>Analytical chemistry >Passive sampling of airborne peroxyacetic acid
【24h】

Passive sampling of airborne peroxyacetic acid

机译:空气中过氧乙酸的被动采样

获取原文
获取原文并翻译 | 示例
           

摘要

The first passive sampling device for the determination of airborne peroxyacetic acid (PAA) is presented. 2-([3{2-[ 4-Amino-2-(methylsulfanyl) phenyl]-1-diazenyl} phenyl]sulfonyl)- 1-ethanol (ADS) is used to impregnate glass fiber filters, and the reagent is oxidized by PAA to the corresponding sulfoxide ADSO. After elution of the filters, ADS and ADSO are separated by reversed-phase HPLC and detected by UV/visible absorbance. Limit of detection is 30 ppb, limit of quantification is 90 ppb ( for 30 min sampling), and the linear range comprises 2 orders of magnitude. Thorough investigations were carried out with respect to the selectivity of the method toward hydrogen peroxide, and air samples were analyzed successfully after disinfection of a laboratory area.
机译:介绍了用于测定空气中过氧乙酸(PAA)的第一台被动采样设备。 2-([3 {2- [4-氨基-2-(甲基硫烷基)苯基] -1-二氮杂基}苯基]磺酰基)-1-乙醇(ADS)用于浸渍玻璃纤维过滤器,该试剂被氧化PAA为相应的亚砜ADSO。滤出液洗脱后,通过反相HPLC分离ADS和ADSO,并通过UV /可见光吸收进行检测。检测限为30 ppb,定量限为90 ppb(30分钟采样),线性范围包括2个数量级。对该方法对过氧化氢的选择性进行了深入研究,并对实验室区域消毒后的空气样品进行了成功分析。