Serum levonorgestrel levels and endometrial thickness during extended use of the levonorgestrel-releasing intrauterine system.

机译:延长使用左炔诺孕酮宫内节育器期间的血清左炔诺孕酮水平和子宫内膜厚度。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The levonorgestrel-releasing intrauterine system (LNG-IUS) is a contraceptive method approved for five years of use. However, there is some evidence that its life span may be longer. The aim of the study was to evaluate serum levonorgestrel (LNG) and estradiol (E(2)) levels and endometrial thickness every 6 months from 7 to 8 1/2 years after insertion. STUDY DESIGN: At the end of the approved 5-year life span, no replacement devices were available; therefore, 86 women were allowed to retain the same device for a further 2 years. At the 7-year follow-up visit, the women who consented were again allowed to retain the same device for a further 18 months and were followed-up at six-monthly intervals. At each visit, vaginal sonography was performed to measure endometrial thickness, and a blood sample was taken to measure LNG and E(2). RESULTS: Eighty-four months after insertion, 67 women aged 34.3+/-0.8 years (mean+/-SEM) (range, 25-49 years) returned for follow-up. Mean+/-SEM LNG levels decreased from an initial 253+/-27 pg/mL (range, 86-760) during the first 2 months following insertion to 137+/-12 (range, 23-393) at 84 months and 119+/-9 pg/mL (range, 110-129) at 102 months of use (+/-SEM). At 84 months of use, mean+/-SEM endometrial thickness was 2.8+/-0.1 mm, increasing to 3.8+/-0.5 mm at 102 months of use. The incidence of amenorrhea decreased from 41.8% at 84 months to 31.5% at 102 months of use. No correlation was found between LNG levels and bleeding patterns; however, a weak correlation was found between high body mass index (kg/m(2)), high weight, and low serum LNG levels. E(2) levels were similar to those of the follicular phase of the menstrual cycle of regularly menstruating women. CONCLUSIONS: During extended use of the LNG-IUS, serum LNG levels were nearly half those found in the first 2 months of use (Wilcoxon signed rank test); serum E(2) levels were normal. Despite the very thin endometrium, menstrual bleeding was reinstated in many cases. At the end of its 5-year life span, there is a window for changing the LNG-IUS, and physicians and users should not be concerned about delaying replacement of the device for a short time beyond the approved life span; however, maintaining the same device long after its approved life span cannot be recommended.
机译:背景:左炔诺孕酮宫内节育系统(LNG-IUS)是一种已批准使用五年的避孕方法。但是,有证据表明它的寿命可能更长。该研究的目的是在插入后7至8 1/2年每6个月评估一次血清左炔诺孕酮(LNG)和雌二醇(E(2))的水平以及子宫内膜厚度。研究设计:在批准的5年寿命结束时,没有可用的替换设备;因此,允许86名妇女再使用同一装置2年。在7年的随访中,同意的妇女再次被允许将同一器械再保留18个月,并每6个月进行一次随访。每次访视时,都要进行阴道超声检查以测量子宫内膜厚度,并取血样以测量LNG和E(2)。结果:插入后八十四个月,有67名34.3 +/- 0.8岁(平均+/- SEM)(范围25-49岁)的妇女返回了随访。平均+/- SEM LNG水平从插入后头两个月的最初253 +/- 27 pg / mL(范围86-760)降低到84个月和119时的137 +/- 12 pg / mL(范围23-393)使用102个月时(+/- SEM)+/- 9 pg / mL(范围110-129)。在使用84个月时,平均+/- SEM子宫内膜厚度为2.8 +/- 0.1 mm,在使用102个月时增加到3.8 +/- 0.5 mm。闭经的发生率从使用84个月时的41.8%降至使用102个月时的31.5%。在液化天然气水平和出血模式之间没有发现相关性。但是,在高体重指数(kg / m(2)),高体重和低血清LNG水平之间发现弱相关性。 E(2)水平类似于正常月经期妇女月经周期的卵泡期。结论:在长期使用LNG-IUS的过程中,血清LNG含量几乎是使用头两个月的一半(Wilcoxon秩和检验)。血清E(2)水平正常。尽管子宫内膜非常薄,但在许多情况下月经出血仍得以恢复。在其5年使用寿命的尽头,有一个更换LNG-IUS的窗口,医生和用户不应担心将设备的更换时间推迟到批准的使用寿命以外的很短时间。但是,建议不要在批准的使用寿命后长时间维护同一设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号