首页> 外文期刊>Analytical chemistry >High-Throughput Liquid Chromatography/Mass Spectrometry Method for the Determination of the Chromatographic Hydrophobicity Index
【24h】

High-Throughput Liquid Chromatography/Mass Spectrometry Method for the Determination of the Chromatographic Hydrophobicity Index

机译:高通量液相色谱/质谱法测定色谱疏水性指数

获取原文
获取原文并翻译 | 示例
           

摘要

A fast gradient reversed-phase liquid chromatography (LC) method, using an acetonitrile gradient was developed to determine the chromatographic hydrophobicity index (CHI), as reported by Valco et al. (Anal. Chem. 1997, 69, 2022-2029). The analytical method provides retention times, based on UV detection at two different wavelengths, which then are converted into CHI values after calibration with a set of test compounds. The CHI of each compound is measured at three different pH values, 2.0, 7.4, and 10.5; so using an 8-min gradient at each pH value one compound can be analyzed in ~24 min. The aim of this work is to improve the throughput of the CHI screening using a LC/MS approach, so the application of the LC/MS technique is an extension of the LC/UV approach previously reported by Valco et al. This approach allows contemporary injection of N compounds into the LC/MS system, the retention time of each compound can be then extracted from the selected ion recording chromatograms. The throughput of the existing screening method could be increased by N times, where N is the number of compounds injected, so only three runs are needed to determine the CHI at three different pH values for a set of N compounds. The highest value of N depends on the total number of channels that can be monitored simultaneously; in the present work, 32 channels were used. This LC/MS method has been tested for a number of commercial products analyzed as mixtures, and data obtained were compared with those coming from the classical LC/UV approach. In the same way, the method was tested for a number of compounds associated with two GlaxoWellcome projects in the antibacterial area. Data reported show that the LC/MS method can be successfully applied for analyzing compounds in mixtures and for compounds with poor UV absorption, which cannot be analyzed with the standard LC/UV method.
机译:Valco等人报道,开发了一种使用乙腈梯度的快速梯度反相液相色谱(LC)方法来确定色谱疏水性指数(CHI)。 (Anal.Chem.1997,69,2022-2029)。该分析方法基于在两个不同波长的紫外线检测,提供了保留时间,然后在用一组测试化合物校准后将其转换为CHI值。在三种不同的pH值2.0、7.4和10.5下测量每种化合物的CHI;因此,在每个pH值下使用8分钟的梯度,可以在约24分钟内分析一种化合物。这项工作的目的是使用LC / MS方法提高CHI筛选的通量,因此LC / MS技术的应用是Valco等人先前报道的LC / UV方法的扩展。这种方法可以将N种化合物现代注入到LC / MS系统中,然后可以从所选的离子记录色谱图中提取每种化合物的保留时间。现有筛选方法的通量可以增加N倍,其中N是注入的化合物数量,因此对于一组N个化合物,在三个不同的pH值下只需确定3次即可确定CHI。 N的最大值取决于可以同时监视的通道总数;在目前的工作中,使用了32个通道。该LC / MS方法已针对多种作为混合物分析的商业产品进行了测试,并将获得的数据与来自经典LC / UV方法的数据进行了比较。以相同的方式,对该方法进行了测试,以研究与抗菌领域中两个葛兰素威康项目相关的多种化合物。所报告的数据表明,LC / MS方法可以成功地用于分析混合物中的化合物以及紫外吸收差的化合物,这是标准LC / UV方法无法分析的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号