A laboratory guarded hot box was used to measure the overall heat transfer coefficient (U value) of two types of plastic film (IR 200 micro m, 8% thermicity and IR 100 micro m, 35%, thermicity), with or without thermal screens (sealed aluminet 50% shade and sealed aluminet 100% shade). Tests were performed in the hot box at different wind velocities and temperature differences. It was found that the overall heat transfer coefficient U increases with the increase in temperature difference. For a given air temperature difference, the U value increases as the wind velocity increases, as expected. There was only a small difference between the U values of the two types of plastic films that were tested. It was found that using a thermal screen would reduce the U value by about 50-60% (depending on type of thermal screen), an energy saving of about 50-60%. Although there was a large difference between the shading percentages of the two thermal screens, the difference between the U values of the combined plastic film and screen was relatively small. Possible reasons for this result are discussed.
机译:使用实验室保护的热箱来测量两种类型的塑料膜的总传热系数(U值)(IR 200微米,热度为8%,IR 100微米,热度为35%,有或没有热屏) (密封的Aluminet 50%阴影和密封的Aluminet 100%阴影)。在热箱中以不同的风速和温度差进行测试。发现总传热系数U随着温度差的增加而增加。对于给定的空气温度差,如预期的那样,U值随风速的增加而增加。被测试的两种塑料薄膜的U值之间只有很小的差异。已经发现,使用热筛可以将U值降低约50-60%(取决于热筛的类型),从而节省约50-60%的能源。尽管两个隔热屏的遮光百分比之间存在较大差异,但组合的塑料膜和隔热屏的U值之间的差异相对较小。讨论了导致此结果的可能原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号