...
首页> 外文期刊>Biochemical and Biophysical Research Communications >Measurement of aberrant glycosylation of prostate specific antigen can improve specificity in early detection of prostate cancer
【24h】

Measurement of aberrant glycosylation of prostate specific antigen can improve specificity in early detection of prostate cancer

机译:前列腺特异性抗原异常糖基化的测量可提高前列腺癌早期检测的特异性

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction We previously identified prostate cancer (PCa)-associated aberrant glycosylation of PSA, where α2,3-linked sialylation is an additional terminal N-glycan on free PSA (S2,3PSA). We then developed a new assay system measuring S2,3PSA using a magnetic microbead-based immunoassay. We compared the diagnostic accuracy of conventional PSA and percent-free PSA (%fPSA) tests. Methods We used MagPlex beads to measure serum S2,3PSA levels using anti-human fPSA monoclonal antibody (8A6) for capture and anti-α2,3-linked sialic acid monoclonal antibody (HYB4) for detection. We determined the cutoff values in a training test and measured serum S2,3PSA levels in 314 patients who underwent biopsy, including 138 PCa and 176 non-PCa patients with PSA of <10.0 ng/ml. Serum S2,3PSA levels were presented as mean fluorescence intensity (MFI). Receiver operating characteristic curves were used to evaluate the diagnostic accuracy of total PSA, %fPSA, and S2,3PSA. Results We determined an MFI cutoff value of 1130 with a sensitivity of 95.0% and specificity of 72.0% for the diagnosis of PCa in the training test. In the validation study, the area under the curve for the detection of PCa with S2,3PSA was 0.84, which was significantly higher than that with PSA or %fPSA. Conclusions Although the present study is small and preliminary, these results suggest that the measurement of serum S2,3PSA using a magnetic microbead-based immunoassay may improve the accuracy of early detection of PCa and reduce unnecessary prostate biopsy.
机译:引言我们先前确定了PSA与前列腺癌(PCa)相关的异常糖基化,其中α2,3-唾液酸化是游离PSA(S2,3PSA)上的另一个末端N-聚糖。然后,我们使用基于磁微珠的免疫测定法开发了一种新的测定系统,用于测量S2,3PSA。我们比较了传统PSA和无百分比PSA(%fPSA)测试的诊断准确性。方法我们使用MagPlex磁珠使用抗人fPSA单克隆抗体(8A6)进行捕获,并使用抗α2,3连接的唾液酸单克隆抗体(HYB4)进行血清S2,3PSA水平的检测。我们在训练测试中确定了临界值,并测量了314例活检患者的血清S2,3PSA水平,包括138名PCa和176名PSA <10.0 ng / ml的非PCa患者。血清S2,3PSA水平表示为平均荧光强度(MFI)。接收器工作特性曲线用于评估总PSA,%fPSA和S2,3PSA的诊断准确性。结果我们在训练试验中确定MFI临界值为1130,对PCa的诊断敏感性为95.0%,特异性为72.0%。在验证研究中,使用S2,3PSA检测PCa的曲线下面积为0.84,显着高于使用PSA或%fPSA的PCa。结论尽管本研究规模较小且尚处于初步阶段,但这些结果表明,使用基于磁微珠的免疫测定法测量血清S2,3PSA可以提高PCa早期检测的准确性并减少不必要的前列腺活检。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号