The complement-fixation test (CFT) permits low-cost screening of serum samples for different agents within a single assay, and is a useful tool for the serological diagnosis of acute respiratory infections. This study evaluated the automated Seramat CFT system with 160 paired serum samples taken from 80 patients with acute respiratory infection in comparison with in-house CFTs against a panel of agents, including influenza A and B, adenovirus, respiratory syncitial virus, cytomegalovirus, Mycoplasma pneumoniae, Coxiella burnetti and Chlamydia spp., and in comparison with indirect immunofluorescence (IIF) against Legionella pneumophila. Overall, the Seramat system identified 75 (88.2%) of the 85 seroconversions recognised by in-house CFTs or IIF. In comparison to the in-house CFTs, the correlation was 89.2% (66/74). For L. pneumophila, the Seramat system detected nine (81.8%) of the 11 cases diagnosed by IIF. The Seramat system also identified eight additional seroconversions that were not detected by the in-house assays; none of these seroconversions was detected by the in-house assay on retesting. The Seramat system represents a significant technical improvement that may enable many clinical laboratories to use the CFT as a routine diagnostic tool.
机译:补体固定试验(CFT)可在一次测定中低成本筛查不同试剂的血清样品,并且是急性呼吸道感染的血清学诊断的有用工具。这项研究评估了自动Seramat CFT系统,对80例急性呼吸道感染患者的160份配对血清样本与针对一系列试剂的内部CFT进行了比较,其中包括一系列甲型和乙型流感,腺病毒,呼吸道合胞病毒,巨细胞病毒,肺炎支原体,柯氏杆菌Burnetti和衣原体spp。,并与针对嗜肺军团菌的间接免疫荧光(IIF)进行比较。总体而言,Seramat系统确定了内部CFT或IIF识别的85种血清学转换中的75种(88.2%)。与内部CFT相比,相关率为89.2%(66/74)。对于L. pneumophila,Seramat系统在IIF诊断的11例病例中检测到9例(81.8%)。 Seramat系统还确定了另外8种血清转化,这些血清转化没有通过内部分析检测到。在重新测试时,通过内部检测未检测到这些血清转化。 Seramat系统代表了一项重大的技术改进,可以使许多临床实验室将CFT用作常规诊断工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号