摘要

A practical method is presented for determining the permissible limits of voltage deviation at a center supplying power to a 6-10/0,4 kV distribution network under which the requirements of the Russian GOST standard on the steady-state deviations of the voltage are satisfied. The proposed method uses static characterictics of the operating parameters. The required correction of the voltage for a 6-10/0,4 kV tapped transformer is determined from the long-term voltage losses (averaged for a season or year) in a section of a 10(6) kV network, on the transformer and in the low-voltage network, and from the tentative range of mean deviations of the voltage at the power supply center for the same period of time. The limits of the voltage ranges are calculated as normal and limit maximum deviations of the voltage at the power supply center for the recommended values of the mean and root-mean square deviation.
机译:提出了一种实用的方法,用于确定向6-10 / 0.4 kV配电网供电的中心的电压偏差的允许极限,在这种情况下,可以满足俄罗斯GOST标准对电压稳态偏差的要求。所提出的方法使用了操作参数的静态特征。 6-10 / 0.4 kV抽头变压器所需的电压校正是根据变压器上10(6)kV网络部分的长期电压损耗(按季节或年平均)确定的并在低压网络中,从相同时间段内电源中心电压的平均偏差的暂定范围开始。对于平均值和均方根偏差的建议值,将电压范围的限制计算为正常值,并限制电源中心电压的最大最大偏差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号