Progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses

机译:戴角膜复曲面硬质透气隐形眼镜患者圆锥角膜的进展

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To investigate the rate of progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses (pancorneal RGP-CL) compared to non-pancorneal RGP-CL. We also evaluated alterations in anterior chamber parameters with the progression of keratoconus and investigated the location of the cone in eyes with keratoconus. Methods: The current study was a retrospective study including patients with clinically evident keratoconus from the outpatient clinic from the Department of Ophthalmology of the Erasmus Medical Center, Rotterdam, the Netherlands. Medical history and contact lens characteristics were documented. All participants underwent ophthalmic examination including corneal topography. Corneal topography was repeated at one of the consecutive visits of the patient. Patients were divided into two groups: those wearing pancorneal RGP-CL and those wearing other contact lens types. As a measure of progression of keratoconus differences in corneal topography parameters between both groups were compared. Results: A total of 82 patients were included of which 42 had follow-up (mean 17.8 months) data. We found a significant difference in progression between eyes fitted with and without pancorneal RGP-CL ( K-flat: p= 0.09, K-steep: p= 0.02, K-mean: p= 0.02, and K-minimum: p= 0.04). Compared with eyes fitted without pancorneal RGP-CL no significant difference in K-values was found for eyes fitted with pancorneal RGP-CL during follow-up. Furthermore, a significant decrease in anterior chamber volume ( p<. 0.001) and corneal volume ( p= 0.008) was found during follow-up. In 86.6% the location of the cone was located infero-temporal. Conclusions: Pancorneal RGP-CL have a better effect on stabilizing progression of keratoconus than non-pancorneal RGP-CL. The finding of an infero-temporal location of the cone in keratoconic corneas may improve results of contact lens fitting and surgical management.
机译:目的:研究与非角膜RGP-CL相比,角膜圆锥角膜硬性透气性角膜接触镜(角膜RGP-CL)患者圆锥角膜的进展速度。我们还评估了圆锥角膜进展的前房参数变化,并研究了圆锥角膜在眼睛中的视锥位置。方法:本研究是一项回顾性研究,纳入了来自荷兰鹿特丹伊拉斯姆斯医学中心眼科门诊的临床上有明显圆锥角膜的患者。记录病史和隐形眼镜特性。所有参与者都接受了眼科检查,包括角膜地形图检查。在患者的连续探访之一时重复进行角膜地形图检查。患者分为两组:戴角膜RGP-CL的患者和戴其他类型的隐形眼镜的患者。作为衡量圆锥角膜进展的方法,比较了两组之间角膜地形图参数的差异。结果:共纳入82例患者,其中42例接受了随访(平均17.8个月)。我们发现在装有和不装有角膜RGP-CL的双眼之间,进展之间存在显着差异(K平坦:p = 0.09,K陡峭:p = 0.02,K均值:p = 0.02和K最小值:p = 0.04 )。与未配角膜RGP-CL的眼睛相比,在随访过程中未配角膜RGP-CL的眼睛的K值没有显着差异。此外,在随访期间发现前房容积(p <.0.001)和角膜容积(p = 0.008)明显减少。圆锥体的位置在颞下颞部占86.6%。结论:角膜RGP-CL在稳定圆锥角膜发展方面比非角膜RGP-CL有更好的效果。在圆锥形角膜角膜锥的颞下位置的发现可能会改善隐形眼镜验配和手术处理的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号