This paper is a report of the relationship between the charge amount (charge to mass ratio) of polypropylene granules (PP; typical particle size of 2 to 3 mm, 300 kg) and the electrostatic discharges that happened while loading of metal silo (diameter, 1.5 m; straight body length, 3 m; capacity, 4.8 m~3). The feedback control system was used in order to control the charge amount of PP granules. The electrostatic discharges inside the silo were also observed by using a conventional image-intensifier system. The results obtained from the experiments show that (1) two kinds of electrostatic discharges inside a metal silo while loading PP granules, i.e., brush discharges and incendiary bulk surface discharges were clearly observed. (2) the number of brush discharges and incendiary bulk surface discharges increased with the increase in the charge to mass ration of PP granules, and then almost reaching saturation. And (3) brush discharges and incendiary bulk surface discharges began to happen at the -1.16 μC/kg and -2.33 μC/kg point, respectively in this study.
机译:本文报道了聚丙烯颗粒(PP;典型的2至3 mm,300 kg)的电荷量(电荷质量比)与在装载金属筒仓时发生的静电放电(直径, 1.5 m;笔直长度3 m;容量4.8 m〜3)。为了控制PP颗粒的装料量,使用了反馈控制系统。通过使用常规的图像增强系统,还可以观察到料仓内部的静电放电。从实验中获得的结果表明:(1)在装载PP颗粒的同时,金属筒仓内部有两种静电放电,即刷子放电和燃烧的大块表面放电。 (2)随着PP颗粒质量比的增加,刷子放电和燃烧性表面放电的数量增加,然后几乎达到饱和。 (3)在本研究中,分别在-1.16μC/ kg和-2.33μC/ kg点处开始发生刷子放电和燃烧性大块表面放电。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号