If the injection point is located at the wall-side of the vessel, the volumetric mass-transfer coefficient increased rather slightly with the increase in the rotation rate. But if the injection point is located at the center of the vessel, it was once decreased and increased with the rotation rate. The volumetric mass transfer coefficient can be represented as the function of input mixing energy densities, P_(gv). The following empirical equation was obtained using a concept of the effective energy density. K_a=5.5 X 10~(-5) P_(av)~(0.75) (P_(av)/3 +P_(gv))~(0.14).
机译:如果注射点位于容器的壁侧,则体积传质系数随转速的增加而略有增加。但是,如果注射点位于血管中心,则它会随着转速的增加而降低和升高。体积传质系数可以表示为输入混合能量密度P_(gv)的函数。使用有效能量密度的概念获得以下经验方程式。 K_a = 5.5 X 10〜(-5)P_(av)〜(0.75)(P_(av)/ 3 + P_(gv))〜(0.14)。