Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45 MHz, single-element, unfocused, 0.7 mm in diameter) with a multi-mode optical fiber (0.6 mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. (C) 2015 Elsevier Ltd. All rights reserved.
机译:血管内超声(IVUS)成像对于高风险的动脉粥样硬化斑块以及胃肠道疾病的检测和表征非常重要。最近,血管内光声(IVPA)成像已被用于区分具有高光学对比度和超声分辨率的生物组织的组成。这些成像技术的结合可以提供形态学信息和分子筛查以表征异常组织,这将有助于医生在开始治疗之前确保对患者至关重要的治疗价值和预后意义。在这项研究中,将高频IVUS成像导管(45 MHz,单元件,未聚焦,直径0.7 mm)与多模光纤(芯直径0.6 mm,0.22 NA)集成在一起,并集成了血管内超声-光声(IVUP)成像导管已开发出来,可提供有关浑浊样品中光分布的空间和功能信息。同时,将IVUS成像与IVPA成像共配准,以构建3D体积样本图像。在一项幻像研究中,使用含有吲哚花青绿(ICG)和亚甲基蓝(MB)的聚乙烯醇(PVA)模拟组织血管幻象,证明了对生物染料进行标测的可行性,该染料可用于心血管和癌症诊断。对于离体研究,采用提议的混合技术,利用切除的带有ICG的猪肠样本来靶向胃肠道肿瘤或动脉粥样硬化斑块中存在的生物标记。结果表明,具有2.2毫米直径导管的IVUP内窥镜可能是用于医学成像的有用工具。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号