...
首页> 外文期刊>Clinical anatomy: official journal of the American Association of Clinical Anatomists & the British Association of Clinical Anatomists >Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement.
【24h】

Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement.

机译:定量评估上颌小根间位置的皮质骨厚度和牙根邻近度,以进行正畸小种植体植入。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Few studies have evaluated interradicular anatomy for cortical bone thickness and root proximity when placing a mini-implant for orthodontic anchorage. The purpose of this study was to provide a clinical guideline to indicate the best location, according to different insertion angles, for placement of a mini-implant with respect to the thickness of cortical bone and root proximity. CT images from 14 men and 14 women (mean age, 27 years; range, 23-35 years) were used to evaluate the buccal interradicular cortical bone thickness and root proximity from and mesial to the central incisor to the second molar. A measure of cortical bone thickness was performed at four different angles. Generally, thin cortical bone thickness was found in the central/central incisors and central/lateral incisors interradicular sites. Cortical bone thickness increased significantly as the insertion angle increased except for interradicular sites at the 2 mm level from the alveolar crest. The volume of cortical bone engagement increased significantly at the 4 and 6 mm levels from the alveolar crest with an insertion angle of 30 degrees and 45 degrees in most interradicular sites. The lateral incisor/canine and second premolar/first molar interradicular sites showed greater space between roots compared with other sites, although this was not statistically significant. Based on the findings of this study, we recommend that mini-implants be placed at the 4 and 6 mm levels from the alveolar crest with 30 degrees and 45 degrees angles for the majority of interradicular sites to ensure better cortical bone to mini-implant contact without root damage.
机译:很少有研究评估放置微型植入物进行正畸锚固时的放射间隙解剖对皮质骨厚度和根部邻近度的影响。这项研究的目的是提供一种临床指南,以根据不同的插入角度指示相对于皮质骨的厚度和根部邻近程度放置微型植入物的最佳位置。使用14位男性和14位女性的CT图像(平均年龄27岁;范围23-35岁)来评估颊侧根尖的皮质厚度和根中切牙到第二磨牙的中根。在四个不同角度进行了皮质骨厚度的测量。通常,在中央/中央门牙和中央/外侧门牙的根尖之间发现薄的皮质骨厚度。皮质骨厚度随着插入角度的增加而显着增加,除了距牙槽c 2 mm处的根尖间位置。皮质骨接合的体积在距牙槽c的4mm和6mm处显着增加,在大多数放射间隙之间的插入角度分别为30度和45度。与其他部位相比,侧切牙/犬牙和第二前磨牙/第一磨牙根尖间位置显示根部之间的空间更大,尽管这在统计学上不显着。根据这项研究的结果,我们建议将微型植入物放置在距牙槽c 4mm和6mm的位置,并以30度和45度角放置在大多数放射根间位置,以确保更好的皮质骨与微型植入物接触没有根损伤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号