首页> 外文期刊>電子情報通信学会技術研究報告. 機構デバイス. Electromechanical Devices >Effect of Magnetic Blow-out of Break Arcs with air flow Occurring between Silver Electrical Contacts with Copper Runners
【24h】

Effect of Magnetic Blow-out of Break Arcs with air flow Occurring between Silver Electrical Contacts with Copper Runners

机译:带有银流道的银电触点之间发生的气流对气流产生的破坏电弧的电磁吹脱效应

获取原文
获取原文并翻译 | 示例
           

摘要

Arc runners are fixed on silver electrical contacts. Break arcs are generated between the contacts in a 450VDC circuit. Break arcs are magnetically blown-out with air flow. Circuit current when contacts are closed is 10A. Flow rate of air Q is changed from 1 to 10L/min. Supply voltage E is changed from 200V to 450V. The following results are shown. Arc duration D tends to decrease with increasing flow rate Q. The number of reignitions increases with increasing supply voltage E for each flow rate Q. The number of reignitions is the least when the flow rate Q is 2L/min.
机译:电弧流道固定在银色的电触点上。在450VDC电路的触点之间会产生断弧。气流中会以电磁方式吹断电弧。触点闭合时的电路电流为10A。空气Q的流量从1升/分钟改变为10升/分钟。电源电压E从200V变为450V。显示以下结果。电弧持续时间D倾向于随着流量Q的增加而减小。点火次数随每个流量Q的供电电压E的增加而增加。当流量Q为2L / min时,点火次数最少。