首页> 外文期刊>Clinica chimica acta: International journal of clinical chemistry and applied molecular biology >Corrigendum to 'Increased detection rate of melamine-containing calcium urolithiasis by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique in clinical practice' [Clin. Chim. Acta 431C (2014) 294-298]
【24h】

Corrigendum to 'Increased detection rate of melamine-containing calcium urolithiasis by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique in clinical practice' [Clin. Chim. Acta 431C (2014) 294-298]

机译:“在临床实践中通过使用基质辅助激光解吸/电离飞行时间质谱技术提高含三聚氰胺的尿石症钙检出率”更正。詹。 Acta 431C(2014)294-298]

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Studies have shown that melamine may be associated with urolithiasis. A more sensitive method is needed to analyze melamine in urinary stones to identify potential causes of urolithiasis. Methods: Here we compare the analytical methods of detecting melamine in urinary stones by Fourier transform infrared (FTIR) spectroscopy and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in the laboratory and clinic. First, we established the melamine detection limit in melamine-cyanurate standard by the methods of FTIR spectrophotometer and MALDI-TOF MS. Subsequently, we applied these two methods to 54 adult patients with upper urinary tract calcium urolithiasis.Results: We found that the detection limit of melamine in melamine cyanurate standard by MALD-TOF MS was ~10,000-fold more sensitive than FTIR. We applied both instruments to 54 stone specimens from 54 calcium urolithiasis patients. In those without distinctive melamine pattern in the FTIR spectra, melamine could be detected by MALD-TOF MS in an additional 12 out of 42 subjects' stone specimens (28.6%). Compared to MALD-TOF MS-negative subjects (n = 30), those positive subjects (n = 12) excreted significantly higher urinary melamine levels (P< 0.05).Conclusion: Compared to FTIR, MALDI-TOF MS is a more sensitive method in detecting the content of melamine in melamine-containing kidney stones.
机译:背景:研究表明,三聚氰胺可能与尿石症有关。需要一种更灵敏的方法来分析尿结石中的三聚氰胺,以确定尿路结石的潜在原因。方法:在实验室和临床中,我们比较了通过傅立叶变换红外光谱(FTIR)和基质辅助激光解吸/电离飞行时间质谱(MALDI-TOF MS)检测尿结石中三聚氰胺的分析方法。首先,我们通过FTIR分光光度计和MALDI-TOF MS方法建立了三聚氰胺氰尿酸酯标准品中的三聚氰胺检测限。随后,我们将这两种方法应用于54例成人上尿路尿路结石患者。结果:我们发现,MALD-TOF MS检测三聚氰胺氰尿酸酯标准品中三聚氰胺的灵敏度是FTIR的约10,000倍。我们将这两种仪器应用于来自54位尿路结石病患者的54个石块标本。在FTIR光谱中没有明显三聚氰胺模式的人群中,可以通过MALD-TOF MS在42个受试者的石样中另外12个(28.6%)检测到三聚氰胺。与MALD-TOF MS阴性受试者(n = 30)相比,那些阳性受试者(n = 12)排泄的尿中三聚氰胺水平明显更高(P <0.05)。结论:与FTIR相比,MALDI-TOF MS是一种更敏感的方法检测含三聚氰胺的肾结石中三聚氰胺的含量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号