Evaluation of the Dade Behring Dimension RxL: integrated chemistry system-pediatric reference ranges.

机译:Dade Behring尺寸RxL的评估:集成化学系统-儿科参考范围。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The Dade Dimension RxL was introduced into our laboratory at the Children's National Medical Center in an effort to increase the overall efficiency and decrease costs through consolidation of existing procedures. The objectives of this study were to evaluate the performance of the Dade Dimension RxL in a Pediatric Hospital and to establish pediatric reference ranges for this analyzer. METHODS: Within-run and between-day imprecision was evaluated for >60 analytes using two levels of controls. Method comparison studies by regression analysis were performed on eight platforms that included: Vitros 500, Bayer Immuno I, Behring Nephelometer 100, Abbott TDx, Labconco chloridometer, Bayer 2000, Cobas Mira and Hitachi 747. Pediatric reference ranges were determined by utilizing the regression equations to transform the previously established pediatric reference ranges (which employed 1000-10,000 measurements/analyte) using alternate methods to their corresponding values on the Dimension system. RESULTS: The CVs for within-run and between-day imprecision for all analytes were <10%. The overall correlation (r) of the analytes tested ranged between 0.91 and 0.99. Pediatric reference ranges were obtained for over 40 analytes. CONCLUSIONS: The Dimension RxL provides precise and accurate measurement for a wide variety of analytes including routine chemistries, drugs and hormones. Since a good correlation was observed with the alternate platforms, consolidation of these various workstations into one unit would contribute to decreased turnaround time and greatly improved staff efficiency.
机译:背景:Dade Dimension RxL被引入儿童国家医疗中心的我们的实验室,旨在通过合并现有程序来提高整体效率并降低成本。这项研究的目的是评估Dade Dimension RxL在儿科医院的性能,并确定该分析仪的儿科参考范围。方法:使用两个级别的对照评估了运行中和日间不精确度> 60种分析物。在八个平台上进行了回归分析的方法比较研究,这些平台包括:Vitros 500,Bayer Immuno I,Behring比浊仪100,Abbott TDx,Labconco氯化仪,Bayer 2000,Cobas Mira和Hitachi 747。使用替代方法将先前建立的儿科参考范围(使用1000-10,000次测量/分析物)转换为Dimension系统上的相应值。结果:所有分析物的运行中和日间不精确度的CV <10%。被测分析物的总体相关性(r)在0.91至0.99之间。获得了40多种分析物的儿科参考范围。结论:Dimension RxL可为各种分析物(包括常规化学药品,药物和激素)提供精确,准确的测量结果。由于在备用平台上观察到良好的相关性,因此将这些各种工作站整合为一个单元将有助于减少周转时间并大大提高员工效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号