Assessment of urinary N-telopeptide: Point-of-care testing, sample types, and relationship to urinary helical peptide excretion.

机译:尿N端肽的评估:即时检验,样品类型以及与尿螺旋肽排泄的关系。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: A point-of-care (POC) device would be useful in the space program for measuring N-telopeptide (NTX), a marker of bone resorption. This study was done to establish whether NTX measurements from a POC device compare favorably with standard (ELISA) techniques. We also compared results from fresh and frozen urine samples, samples collected on consecutive days, and second voids (of the day) and 24-h urine pools. Helical peptide (HP), another crosslink, was compared in second voids and 24-h urine pools. METHODS: Ten subjects collected urine for 96 h. NTX was measured with the POC device and by ELISA, and HP measured by ELISA. Seven subjects collected 24-h urine pools, and samples were analyzed fresh and after 27 days of freezing. RESULTS: Excretion of NTX was greater (P<0.05) when measured by the POC device than when measured by ELISA, but was not different between second voids and 24-h urine pools, or among days. HP was similar in second voids and 24-h pools. Less NTX (P<0.05) was found in fresh24-h pools [mean (S.D.) values, 38.4 (11.6) and 33.6 (9.2) nmol/mmol creatinine for the POC device and ELISA] than in previously frozen 24-h pools [42.7 (17.4) and 41.5 (12.5) nmol/mmol creatinine for the POC device and ELISA]. CONCLUSIONS: Comparisons between NTX measurements from frozen and fresh samples and those analyzed by POC and ELISA techniques should be made with caution.
机译:背景:即时诊断(POC)设备在太空计划中用于测量N-端肽(NTX)(一种骨吸收的标志物)将非常有用。进行这项研究是为了确定来自POC设备的NTX测量值是否可以与标准(ELISA)技术相比。我们还比较了新鲜和冷冻尿液样本,连续几天收集的样本以及(一天中的)第二个空隙和24小时尿液池的结果。在第二个空隙和24小时尿液中比较了另一个交联的螺旋肽(HP)。方法:十名受试者收集尿液96小时。用POC装置和ELISA测定NTX,用ELISA测定HP。 7名受试者收集了24小时的尿液池,并在冷冻27天后对样品进行了新鲜分析。结果:用POC装置测定的NTX排泄量比用ELISA法测定的大(P <0.05),但在第二个空隙和24小时尿液池之间或几天之间无差异。 HP在第二个空隙和24小时池中的表现相似。与以前冷冻的24小时池相比,在新鲜的24小时池中发现的NTX(P <0.05)更少[平均(SD)值,POC设备和ELISA的nmol / mmol肌酐为38.4(11.6)和33.6(9.2)nmol / mmol肌酐] [ POC装置和ELISA分别为42.7(17.4)和41.5(12.5)nmol / mmol肌酐。结论:冷冻和新鲜样品的NTX测量值与通过POC和ELISA技术分析的NTX测量值之间的比较应谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号