首页> 外文期刊>石川島播磨技報 >Control System Design and Operation Test Result of 1000 kW Class MCFC Power Plant
【24h】

Control System Design and Operation Test Result of 1000 kW Class MCFC Power Plant

机译:1000 kW级MCFC电厂控制系统设计与运行试验结果

获取原文
获取原文并翻译 | 示例
           

摘要

The molten carbonate fuel cell (MCFC) power plant has significant advantages such as high efficiency and low emissions of NO_x and SO_x, so commercialization is expected for power generation. A 1000 kW class MCFC power plant was constructed and tested by MCFC Research Association in Kawagoe Power Station of Chubu Electric Power Co., Inc. IHI supplied the MCFC Stack facility (500 kW), control system, and operation supervision for the plant test operation. Good operation controllability was confirmed. This paper reports the outline of the control system and operation test result.
机译:熔融碳酸盐燃料电池(MCFC)电厂具有显着优势,例如效率高,NO_x和SO_x排放低,因此有望实现发电的商业化。由中部电力株式会社川越发电所的MCFC研究协会建造并测试了1000 kW级的MCFC电厂。IHI为该工厂的测试运行提供了MCFC烟囱(500 kW),控制系统和运行监督。确认了良好的操作控制性。本文报告了控制系统的概述和运行测试结果。