摘要

PURPOSE: The frequency doubling (FD) illusion is the basis for new diagnostic methods for glaucoma. The FD illusion is seen when low spatial frequency grating patterns are contrast modulated at high rates. The present experiments examined which spatial frequencies might be optimal and whether high flicker rates are required. METHODS: We determined contrast thresholds for the following: W1, a wide-field 0.25 c/deg grating at 27 Hz contrast reversal; W2, as W1 but no flicker; MAC, 27 Hz, 4 c/deg grating presented to the central 4 degrees; and E1 to E7, seven spatial frequencies in the range 0.063-0.813 c/deg, 27 Hz, presented in a 5 degrees aperture at 15 degrees (nasal) eccentricity. RESULTS: W1 was the best predictor of glaucoma. Of the eccentrically presented stimuli, E6 (0.688 c/deg) was the best predictor of glaucoma while the lower spatial frequencies performed less well. Only MAC was significantly age-dependent.
机译:目的:倍频(FD)错觉是青光眼新诊断方法的基础。当低空间频率光栅图案以高比率进行对比度调制时,会看到FD幻觉。本实验检查了哪些空间频率可能是最佳的,以及是否需要高闪烁率。方法:我们确定以下对比度阈值:W1,在27 Hz对比度反转下的宽视野0.25 c / deg光栅; W2与W1一样,但没有闪烁; MAC,27 Hz,4 c / deg光栅呈现到中心4度;和E1到E7,在0.063-0.813 c / deg,27 Hz范围内的七个空间频率以15度(鼻)偏心率的5度孔径呈现。结果:W1是青光眼的最佳预测指标。在偏心刺激中,E6(0.688 c / deg)是青光眼的最佳预测指标,而较低的空间频率表现较差。仅MAC显着依赖年龄。