New software for lens retro-illumination digital image analysis.

机译:用于镜头复古照明数字图像分析的新软件。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To describe functions of new software for cataract assessment and compare its validity with that of the Nidek EAS-1000 software (Nidek, Japan). METHODS: A new Microsoft Windows 3.1/95 (Microsoft, USA) compliant software, Retroillumination Image Analysis (RIA), has been developed. The cataract reading is based on the contrasts in illumination between the opaque and transparent areas of the lens. Image loading, pupil detection and image analyses are automated. Differentiation between the different cataract types (cortical/posterior subscapsular) and other opacities is possible. RESULTS: The program was tested on 233 Nidek EAS-1000 images. In all, 148 eyes had clear media or cortical cuneiform cataract, 37 also had confounding opacities and 48 had no confounding opacities but pupils were unevenly illuminated. The results of analysis with both Nidek EAS-1000 and RIA software were compared against clinical Wilmer grading.The correlation of cortical opacity size in Nidek EAS-1000 3.01c and RIA software, respectively, were 0.50* and 0.57* for whole data set, 0.54* and 0.55* for subgroup with no confounders or artefacts, 0.54* and 0.66* for subgroup with artefacts, 0.27 (P < 0.105) and 0.65* for subgroup with confounders (*P < 0.001). CONCLUSION: The RIA software significantly improves the accuracy of cataract measurement in lens images with uneven pupil illumination or confounding opacities. Automation of (i) image loading, (ii) pupil detection and (iii) defining of the opacity area increases the efficiency of digital eye photography, eliminates human errors and speeds assessment.
机译:目的:描述用于白内障评估的新软件的功能,并将其与Nidek EAS-1000软件(日本Nidek)的有效性进行比较。方法:已经开发了一种新的,与Microsoft Windows 3.1 / 95(Microsoft,美国)兼容的软件,逆光图像分析(RIA)。白内障的读数基于晶状体的不透明区域和透明区域之间的照明对比度。图像加载,瞳孔检测和图像分析是自动化的。有可能在不同的白内障类型(皮质/后囊膜下)和其他混浊之间进行区分。结果:该程序在233张Nidek EAS-1000图像上进行了测试。总共148眼具有清晰的介质或皮质楔形白内障,37眼也有混淆性混浊,48眼没有混淆性混浊,但瞳孔照明不均。将Nidek EAS-1000和RIA软件的分析结果与临床Wilmer分级进行了比较.Nidek EAS-1000 3.01c和RIA软件在整个数据集中皮层不透明度大小的相关性分别为0.50 *和0.57 *,无混杂因素或伪影的亚组为0.54 *和0.55 *,有伪影的亚组为0.54 *和0.66 *,有混杂因素的亚组为0.27(P <0.105)和0.65 *(* P <0.001)。结论:RIA软件可显着提高瞳孔照度不均匀或混浊度不佳的晶状体图像中白内障测量的准确性。 (i)图像加载,(ii)瞳孔检测和(iii)定义不透明区域的自动化提高了数字眼睛摄影的效率,消除了人为错误并加快了评估速度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号