Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test

机译:眼压峰值的再现性和饮水试验的波动

获取原文
获取原文并翻译 | 示例
           

摘要

Background The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. Design A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Participants Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. Methods The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Main Outcome Measures Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Results Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 +/- 4.64 and 28.38 +/- 4.56mmHg, respectively (P=1.00). Test and retest intraocular pressure fluctuation values were 5.75 +/- 3.9 and 4.99 +/- 2.7mmHg, respectively (P=0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient=0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient=0.37). Conclusion Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair.
机译:背景技术饮水测试已被用作评估眼睛排水系统的压力测试。但是,为了在临床上可以应用,测试必须提供可重复的结果并具有一致的测量结果。这项研究的目的是为了验证高眼压和开角型青光眼患者在饮水试验过程中眼压峰值和波动的再现性。设计对三级青光眼治疗的三级医疗机构的患者进行前瞻性分析。参加者24例高眼压症患者和64例未治疗的开角型青光眼患者。方法由相同的检查员连续两天对未接受治疗的患者进行饮水试验。使用类内相关系数评估可重复性。主要结果测量通过饮水试验获得的眼压的峰值和波动进行了再现性分析。结果对24例高眼压患者和64例未接受治疗的开角型青光眼患者的88只眼进行了评估。测试和重新测试的眼内压峰值分别为28.38 +/- 4.64和28.38 +/- 4.56mmHg(P = 1.00)。测试和重新测试的眼内压波动值分别为5.75 +/- 3.9和4.99 +/- 2.7mmHg(P = 0.06)。基于类内系数,峰值眼压(类内相关系数= 0.79)的再现性极好,并且眼内压波动(类内相关系数= 0.37)的再现性良好。结论饮水试验中检测到的眼压峰值具有良好的可重复性,而波动的可重复性被认为是合理的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号