To evaluate and compare the perfluorocarbon liquid, silicone oil, and viscoelastic against standard saline, in their ability to dampen the impact force of a foreign body, dropped within the eye. In an experimental surgical model in where cohesive and adhesive forces of the substances are not enough to float heavy-than-water foreign bodies.A model of ophthalmic surgery was constructed. A BB pellet was dropped from 24?mm onto a force transducer through four different fluids: balanced salt solution, perfluoro-n-octane, viscoelastic, and silicone oil. The impact energy (force) for each case was measured and recorded by the force transducer. The mean force of impact for each fluid was compared using the Student t-test.Silicone oil resulted in the lowest force of impact. Both silicone oil and viscoelastic dampened the impact an order of magnitude more than perfluoro-n-octane and balanced salt solution.Silicone oil and viscoelastic cushioned the force from a dropped BB. They may be useful adjuncts to prevent iatrogenic retinal injury during vitrectomy for intraocular foreign body removal.
机译:为了评估和比较全氟化碳液体,硅油和粘弹性与标准盐水之间的相互作用,它们能够抑制落入眼内的异物的撞击力。在物质的内聚力和粘附力不足以漂浮重于水的异物的实验外科手术模型中,构建了眼科手术模型。通过四种不同的流体将BB颗粒从24?mm的液体中滴到力传感器上:平衡盐溶液,全氟正辛烷,粘弹性和硅油。通过力传感器测量并记录每种情况下的冲击能量(力)。使用Student t检验比较每种流体的平均冲击力。硅油的冲击力最低。硅油和粘弹性比全氟正辛烷和平衡盐溶液对冲击的阻尼要大一个数量级。硅油和粘弹性可减轻BB掉落的力。它们可能是预防玻璃体切除术中眼内异物去除过程中医源性视网膜损伤的有用辅助手段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号