BACKGROUND: This study aims to assess the optic disc characteristics in healthy adult Malays and to correlate them with age, gender and refractive errors. DESIGN: Cross-sectional study. PARTICIPANTS: A total of 200 voluntary participants (106 women and 94 men) among Malay students aged 20 to 37 years at Health Campus, Universiti Sains Malaysia. METHODS: The relationship between Heidelberg Retinal Tomograph parameters with age, gender and refractive error were analysed with correlation tests and multiple linear regression analyses. MAIN OUTCOME MEASURES: Twelve parameters, that is, disc area, rim area, cup area, cup to disc area, cup volume, rim volume, height variation contour, cup shape measure, mean cup depth, maximum cup depth, mean retinal nerve fibre layer thickness and retinal nerve fibre layer cross-sectional area. RESULTS: Disc area, rim area and cup : disc area ratio averaged 2.24 +/- 0.52 (mean +/- standard deviation), 1.64 +/- 0.32 and 0.25 +/- 0.12 mm(2) , respectively. Five parameters (disc area, cup area, cup volume, cup : disc area ratio and mean retinal nerve fibre layer thickness) showed statistically significant difference between men and women. Age was negatively and significantly correlated with rim area with coefficient r = -0.21, P = 0.003. All optic disc parameters were significantly correlated (P < 0.05) with disc area, except cup shape measure. CONCLUSIONS: One or more of optic disc parameters were affected significantly by age, gender and disc area in healthy adult Malays' eyes. These factors need to be considered during the evaluation of optic disc.
机译:背景:这项研究旨在评估健康成人马来人的视盘特征,并将其与年龄,性别和屈光不正相关联。设计:横断面研究。参加者:马来西亚大学医学院健康校区20至37岁的马来学生中共有200名自愿参加者(106名女性和94名男性)。方法:采用相关检验和多元线性回归分析,分析海德堡视网膜断层扫描仪参数与年龄,性别和屈光不正之间的关系。主要观察指标:十二个参数,即椎间盘面积,边缘区域,杯状区域,杯至椎间盘区域,杯状体积,边缘体积,高度变化轮廓,杯状形状度量,平均杯状深度,最大杯状深度,平均视网膜神经纤维层厚度和视网膜神经纤维层的横截面积。结果:椎间盘面积,轮辋面积和杯:椎间盘面积比分别平均为2.24 +/- 0.52(平均+/-标准偏差),1.64 +/- 0.32和0.25 +/- 0.12 mm(2)。五个参数(盘面积,杯面积,杯体积,杯:盘面积比和平均视网膜神经纤维层厚度)显示出男女之间的统计学差异。年龄与轮辋面积呈负相关且显着相关,系数r = -0.21,P = 0.003。除杯形测量外,所有视盘参数均与视盘面积显着相关(P <0.05)。结论:健康的成年马来人眼睛中,一个或多个视盘参数受到年龄,性别和视盘面积的显着影响。在评估光盘时需要考虑这些因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号