首页> 外文期刊>藥學雜誌 >Investigation of the cause of polyurethane catheter cracking during constant infusion of etoposide (VP-16) injection (2)--Analysis of ethanol eluting materials from catheter
【24h】

Investigation of the cause of polyurethane catheter cracking during constant infusion of etoposide (VP-16) injection (2)--Analysis of ethanol eluting materials from catheter

机译:依托泊苷(VP-16)注射液持续输注过程中聚氨酯导管破裂的原因研究(2)-导管中乙醇洗脱物的分析

获取原文
获取原文并翻译 | 示例
           

摘要

We studied the cause of cracking of clinically used polyurethane (PU) catheters during the constant infusion of etoposide (VP-16) injection (Lastet inj.) without dilution. After the vehicles used for VP-16 injection, ethanol or polyethylene glycol 400 (PEG400), were infused into the PU catheters at a constant infusion rate (30 ml/h) for 24 h, obvious degradation of the internal wall of the catheter was observed under an electron microscope. When the PU catheter was immersed in ethanol for 24 h, condensed polymers of 1,4-butanediol (BD), contained in PU catheters as an elasticizer, were detected in the ethanol elute using the ESI/MS method. Moreover, time-dependent elution of BD from PU catheters with the infusion of ethanol into the catheter for 24 h at 30 ml/h was observed using the GC/MS method. The cumulative amount of BD eluted from the PU catheter with ethanol vehicle for 24 h was 130 micrograms. In conclusion, degradation and subsequent cracking of PU catheters during the infusion of VP-16 injection were caused by ethanol and PEG400 contained in the injection solution. Furthermore, to prevent the elution of BD from PU catheters, we suggest that PU catheters should not be used for the administration of VP-16 injection without dilution in consideration of safety and efficacy.
机译:我们研究了在不稀释的情况下不断注入依托泊苷(VP-16)注射液(Lastet inj。)期间临床使用的聚氨酯(PU)导管破裂的原因。将用于VP-16注射的载体,乙醇或聚乙二醇400(PEG400)以恒定的输注速度(30 ml / h)输注到PU导管中24小时后,导管内壁明显降解。在电子显微镜下观察。将PU导管在乙醇中浸泡24小时后,使用ESI / MS方法在乙醇洗脱液中检测到PU导管中包含的作为增韧剂的1,4-丁二醇(BD)的缩聚物。此外,使用GC / MS方法观察到了从PU导管中BD随时间的洗脱,其中乙醇以30 ml / h的速度向导管中注入24 h。用乙醇媒介物从PU导管洗脱24小时的BD累积量为130微克。总之,在输注VP-16注射过程中,PU导管的降解和随后的开裂是由注射溶液中所含的乙醇和PEG400引起的。此外,为防止BD从PU导管中洗脱出来,出于安全性和有效性的考虑,我们建议PU导管不经稀释无需用于VP-16注射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号