Transepidermal water loss(TEWL) provides us accurate in vivo information about the integriety of the barrier function of the stratum corneum (SC).The largest drawback for using the conventional instruments is their high cost.Moreover,it is also required to conduct measurements in a special environment where there is no air turbulence because so far available instruments are based on an open chamber system that measures the water vapor pressure gradient produced above the skinsurface by te vapor passing through the SC barrier.Recnetly,we have had a chance to test a newly devised portable equipment (Model H4300-S;NIKKISO-YSI CO.,LTD.,Tokyo,Japan) with a closed chamber system whose measuring principleis based on a computed TEWL estimation from a time-wise increase in relative humidity in the space of the probe that is applied on the skin surface.We conducted an in vivo comparative study by using the new portable device and the conventional method using the DermaLab(Cortex Technology,Hadsund,Denmark) in healthy individuals and dermatological patients.We found that the sensitivity of the new device was not inferior to the conventional one because it could detect the poor SC barrier function of normalfacial skin as comparedtothe skin of the extremities.Moreover,barrier disruption that is present in the lesional skin of AD or psoriasis was demonstrable in a severity-dependent fashion.Only one difference from the conventionalone is that the obtained values measured with this new device were lower than those obtained with the DermaLab,probably due to the difference in the method ological principles. It was also unalbe to measure TEWL at the sites with measured values less than 1 g/sq-m/h.However,there was a good correlation betwen the data obtained with different methods (p<0.001).The biggest advantage to use the closed system is that,because water evaporation from the skintakes place in any position,we canperform TEWL measurements without paying attention to the position of the skin surface in contrast to the conventional opensystem that requires the position of the skinsurface to be horizontal.Thus,we can conclude that the closed chamer systemis much more practical than the conventional open cylinder system.It can be carried easily to any palce and enables us to conduct TEWL measurements without requiring any special environment preventive against air turbulence in addition to its cheaper price.
机译:表皮失水(TEWL)为我们提供了有关角质层(SC)屏障功能完整性的准确体内信息。使用常规仪器的最大缺点是成本高。此外,还需要在常规仪器中进行测量在一个没有空气湍流的特殊环境下,因为到目前为止,可用的仪器都是基于开放式腔室系统,该系统可测量通过SC屏障的蒸汽在皮肤表面上方产生的水蒸汽压力梯度。再次,我们有机会进行测试一种新设计的便携式设备(H4300-S型;日本东京的NIKKISO-YSI CO。,LTD。),其密闭室系统的测量原理基于空间相对湿度随时间的逐步增加而计算出的TEWL估算值我们使用新型便携式设备和使用DermaLab(Cortex Technology,Hadsu的传统方法)进行了体内对比研究我们发现,这种新设备的灵敏性不比传统设备差,因为它可以检测到正常面部皮肤与四肢皮肤相比较差的SC屏障功能。此外,屏障破坏在AD或牛皮癣的病灶皮肤中存在的这种现象以严重程度依赖的方式被证实。与传统方法的唯一区别是,使用这种新设备测得的值低于使用DermaLab获得的值。在方法学原理上。甚至在测量值小于1 g / sq-m / h的位置也不能测量TEWL。但是,使用不同方法获得的数据之间具有良好的相关性(p <0.001)。封闭系统是因为水从皮肤上的任何位置蒸发掉,与传统的开放系统(皮肤表面必须水平)相比,我们可以执行TEWL测量而无需关注皮肤表面的位置。可以得出结论,封闭式搅拌器系统比传统的开放式汽缸系统实用得多,它可以很容易地携带到任何地方,使我们能够进行TEWL测量,除了价格便宜之外,不需要任何特殊的防止空气湍流的环境。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号