首页> 外文期刊>Clinical and experimental hypertension: CEH >Determination of baroreceptor-stroke volume reflex sensitivity by power spectral analysis: a quantitative probe of baroreceptor-cardiac reflex.
【24h】

Determination of baroreceptor-stroke volume reflex sensitivity by power spectral analysis: a quantitative probe of baroreceptor-cardiac reflex.

机译:通过功率谱分析确定压力感受器-中风体积反射敏感性:压力感受器-心脏反射的定量探针。

获取原文
获取原文并翻译 | 示例
           

摘要

Baroreceptor-cardiac reflex, which consists of baroreceptor-induced chronotropic and inotropic actions, is a very useful index of cardiac sympathovagal balance. Baroreceptor-heart rate reflex sensitivity, which reflects baroreceptor-induced chronotropic action, has been used as a marker of baroreceptor-cardiac reflex. However, it cannot be used in patients with chronotropic incompetence and/or implanted cardiac pacemaker. We hypothesized that baroreceptor-stroke volume (SV) reflex sensitivity, which reflects baroreceptor-induced inotropic action, may also be a useful method for measurement of baroreceptor-cardiac reflex, similar to the baroreceptor-heart rate reflex sensitivity. To test this hypothesis, we measured baroreceptor-SV reflex sensitivity expressed as ratio of low frequency (LF) power to total power of SV fluctuation (LF/TP(SV): %/mmHg) by spectral analysis of mean blood pressure and SV fluctuations, the gain in low-frequency band between two signals in supine and 60 degrees upright positions, and compared these values to baroreceptor-heart rate reflex sensitivity in 14 healthy subjects. Baroreceptor-SV reflex sensitivity correlated significantly with baroreceptor-heart rate reflex sensitivity (r = 0.73, p < 0.0001). In addition, baroreceptor-SV reflex sensitivity correlated significantly and positively with high frequency (HF) power (r = 0.57, p < 0.005) and negatively with LF/HF ratio (r = -0.57, p < 0.005) in power spectral analysis of R-R interval variability. Moreover, baroreceptor-SV reflex sensitivity in LF/TP(SV) correlated positively with the R-R interval (r = 0.70, p < 0.0001) and negatively with diastolic blood pressure (r = -0.50, p < 0.01). We conclude that baroreceptor-SV reflex sensitivity in LF/TP(SV) can be used as a quantitative probe of baroreceptor-cardiac reflex, similar to the baroreceptor-heart rate reflex sensitivity in healthy subjects, and it may enable us to estimate inotropic aspect in baroreceptor-cardiac reflex in patients with chronotropic incompetence and/or implanted pacemaker.
机译:由压力感受器诱导的变时性和变力作用组成的压力感受器-心脏反射是心脏交感神经-迷走神经平衡的非常有用的指标。反映压力感受器诱导的变时作用的压力感受器心率反射敏感性已被用作压力感受器心脏反射的标志。但是,它不能用于患有变时功能不全和/或植入了心脏起搏器的患者。我们假设反映压力感受器诱导的肌力作用的压力感受器中风体积(SV)反射敏感性也可能是一种测量压力感受器心脏反射的有用方法,类似于压力感受器心率反射敏感性。为了验证这一假设,我们通过平均血压和SV波动的频谱分析测量了压力感受器-SV反射敏感性,表示为低频(LF)功率与SV波动总功率(LF / TP(SV):%/ mmHg)的比率。在仰卧和60度直立位置的两个信号之间的低频频带中的增益,并将这些值与14位健康受试者的压力感受器-心律反射敏感性进行比较。压力感受器-SV反射敏感性与压力感受器-心率反射敏感性显着相关(r = 0.73,p <0.0001)。此外,压力感受器-SV反射敏感性与高功率(HF)功率显着正相关(r = 0.57,p <0.005),而与LF / HF比呈负相关(r = -0.57,p <0.005) RR间隔变化。此外,LF / TP(SV)中的压力感受器-SV反射敏感性与R-R间隔呈正相关(r = 0.70,p <0.0001),与舒张压呈负相关(r = -0.50,p <0.01)。我们得出的结论是,LF / TP(SV)中的压力感受器-SV反射敏感性可以用作压力感受器-心脏反射的定量探针,类似于健康受试者中的压力感受器-心率反射敏感性,并且它可能使我们能够估计正性肌力方面变时功能不全和/或植入起搏器的患者的压力感受器-心脏反射检查

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号