Ring-shaped pulse oximeter and its application: measurement of SpO2 and blood pressure during sleep and during flight.

机译:环形脉搏血氧仪及其应用:睡眠和飞行过程中SpO2和血压的测量。

获取原文
获取原文并翻译 | 示例
           

摘要

Respiratory and cardiovascular functions show circadian and day-to-day changes. We have developed a wireless ring-shaped pulse oximeter in collaboration with MC Medical Inc. and Advanced Medical Inc. We investigated the accuracy of this pulse oximeter and its application in daily life. Percutaneous arterial oxygen saturation (SpO2) of 47 volunteers was measured simultaneously with the ring-shaped pulse oximeter and a standard pulse oximeter. A total of 103 volunteers underwent measurement of SpO2 for 24 hr, and 11 healthy volunteers underwent measurement of SpO2 and blood pressure (BP) during flight. SpO2 and heart rate (HR) were measured and recorded every 20 sec, cabin barometric pressure and cabin oxygen concentration equivalent to sea level were measured minute-to-minute, and BP was measured every 3 min with a portable BP recorder during each flight. The SpO2 values measured with the ring-shaped pulse oximeter were similar to those measured with the standard method. The mean SpO2 during sleep was significantly lower in the group with high-normal BP or mild hypertension than in the group with normal BP. During flight, the mean change in SpO2 was -2.4 +/- 1.7% during nose-up flight, and 2.1 +/- 2.6% during nose-down flight. There was a significant correlation between change in SpO2 and change in systolic BP during nose-up flight. The wireless ring-shaped pulse oximeter was useful for investigating changes in SpO2 and its effect on BP in daily life during sleep and during air travel.
机译:呼吸和心血管功能显示昼夜节律和日常变化。我们与MC Medical Inc.和Advanced Medical Inc.合作开发了无线环形脉搏血氧仪。我们研究了这种脉搏血氧仪的准确性及其在日常生活中的应用。用环形脉搏血氧仪和标准脉搏血氧仪同时测量了47名志愿者的经皮动脉血氧饱和度(SpO2)。在飞行过程中,共有103名志愿者对SpO2进行了24小时的测量,而11名健康志愿者对SpO2和血压(BP)进行了测量。每隔20秒测量和记录一次SpO2和心率(HR),每分钟对舱内气压和等效于海平面的舱内氧气浓度进行逐分钟测量,并在每次飞行中每3分钟使用便携式BP记录仪测量BP。用环形脉搏血氧仪测量的SpO2值类似于用标准方法测量的值。高血压或轻度高血压组的睡眠期间平均SpO2显着低于血压正常的组。在飞行过程中,机鼻向上飞行时SpO2的平均变化为-2.4 +/- 1.7%,而机头向下飞行期间SpO2的平均变化为2.1 +/- 2.6%。机鼻向上飞行期间,SpO2的变化与收缩压的变化之间存在显着的相关性。无线环形脉搏血氧仪可用于研究SpO2的变化及其对睡眠和空中旅行中日常生活中BP的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号