Aims: To investigate the reliability and magnitude of intraoral mechanical pain sensitivity by using a palpometer with add-on devices with different physical properties. Methods: Sixteen healthy volunteers participated. Three palpometers (0.5, 1.0, and 2.0 kg) were used. Add-on devices were put on the circular metal stamp of the palpometer. Four diameters (3, 4, 5, and 10 mm) and two shapes of the rubber-top (flat and round) of the add-on devices were tested at each force level, ie, a total of 24 combinations. Participants were stimulated at the gingival mucosa around the maxillary central incisors and first molars on both sides by using the palpometers in randomized order. Participants rated perceived stimulus intensity on a 0-50-100 numerical rating scale (NRS). Ten volunteers were examined twice on the same day and recalled for a second session for assessment of within- and between-session reliability. Intraclass correlation coefficients were calculated for reliability measures, and NRS scores were analyzed with analysis of variance. Results: Reliability of NRS scores was excellent (interclass correlation coefficients 0.76 to 0.99). Analysis of NRS values corrected for pressure level revealed that there were main effects of site (P = .006), force (P < .001), size (P < .001), and shape (P < .001) but not side (P = .051). Conclusion: Reliability of intraoral novel palpometer measures of pressure sensitivity was excellent, and sensitivity to pressure stimulation was dependent on the applied force and physical properties of the add-on device. The study indicated that semi-quantitative assessment of intraoral mechanical sensitivity is feasible and could be applied in further studies on different intraoral pain conditions.
机译:目的:通过使用具有不同物理特性的附加设备的触诊仪,调查口内机械疼痛敏感性的可靠性和强度。方法:16名健康志愿者参加。使用了三个手压计(0.5、1.0和2.0千克)。将附加设备放在触诊仪的圆形金属印模上。在每种力水平下测试了附加装置的四个直径(3、4、5和10 mm)和橡胶顶部的两种形状(平坦和圆形),即总共24种组合。随机使用触诊仪刺激上颌中切牙和两侧第一磨牙周围的牙龈粘膜。参与者以0-50-100的数字评定量表(NRS)评定了感知的刺激强度。十名志愿者在同一天接受了两次检查,并被召回第二次会议以评估会议期间和会议之间的可靠性。计算类内相关系数用于可靠性测度,并通过方差分析对NRS得分进行分析。结果:NRS评分的可靠性极佳(组间相关系数为0.76至0.99)。对校正后的压力水平的NRS值进行分析后发现,存在以下主要影响:部位(P = .006),受力(P <.001),大小(P <.001)和形状(P <.001),而没有侧面影响(P = .051)。结论:口内新型触诊仪测量压力敏感性的可靠性极好,并且对压力刺激的敏感性取决于附加装置的作用力和物理特性。该研究表明,对口腔内机械敏感性的半定量评估是可行的,并可用于对不同口腔内疼痛状况的进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号