...
首页> 外文期刊>Journal of Virological Methods >Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT)
【24h】

Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT)

机译:使用磁免疫色谱法(MICT)快速检测HIV-1 p24抗原

获取原文
获取原文并翻译 | 示例
           

摘要

Detection of human immunodeficiency virus (HIV) infections has been enhanced by incorporating p24 antigen detection with current HIV antibody detection using enzyme immunoassays (EIAs). However, screening for HIV antibodies has increased through the use of rapid, lateral-flow HIV antibody detection assays that currently do not have the capability to detect HIV p24 antigen. In this report, a lateral-flow based assay using super-paramagnetic particles as the detection marker was developed for the detection of HIV-1 p24 antigen. This magnetic immuno-chromatographic test (MICT) uses an inexpensive, low-maintenance instrument that detects the magnetic moment of the super-paramagnetic particles in a magnetic field. MICT is simple to perform, provides a numerical output for easier determination of reactive results and can be completed in 40 min. The lower limit of detection for HIV-1 p24 spiked into assay sample buffer and 50% plasma was 30 pg/ml for both. Detection of HIV-1 p24 antigen at 50 pg/ml was reproducible in both inter-run and intra-run assays with coefficients of variation of <13%. Furthermore, the MICT p24 assay was able to detect intact virus spiked into 50% plasma (lower detection limit of similar to 250,000 viral RNA copies/ml). MICT detection of increasing HIV-1 p24 levels in commercially available seroconversion panels by MICT was only slightly later than that detected by much more complex EIAs. MICT could provide a simple, low-cost, and portable method for rapid HIV-1 p24 detection in a variety of testing environments
机译:通过将p24抗原检测与当前使用酶免疫测定法(EIA)进行的HIV抗体检测相结合,增强了人类免疫缺陷病毒(HIV)感染的检测。但是,通过使用快速的,侧向流动的HIV抗体检测方法(目前尚无法检测HIV p24抗原),对HIV抗体的筛查有所增加。在此报告中,开发了一种基于超顺磁性粒子作为检测标记的基于侧流的检测方法,用于检测HIV-1 p24抗原。这种磁性免疫色谱测试(MICT)使用便宜的低维护仪器,可检测磁场中超顺磁性粒子的磁矩。 MICT易于执行,可提供数字输出以更轻松地确定反应结果,并且可在40分钟内完成。掺入测定样品缓冲液和50%血浆中的HIV-1 p24的检测下限均为30 pg / ml。在批次间和批次内分析中,以50 pg / ml的浓度检测HIV-1 p24抗原均具有可重复性,变异系数<13%。此外,MICT p24分析能够检测掺入50%血浆的完整病毒(检测下限类似于250,000病毒RNA拷贝/ ml)。 MICT检测到市售血清转化小组中HIV-1 p24水平升高的情况仅比更复杂的EIA检测到的时间稍晚。 MICT可以为各种测试环境中的HIV-1 p24快速检测提供一种简单,低成本和便携式的方法

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号