...
首页> 外文期刊>Journal of Virological Methods >Comparison of signal-to-cutoff values in first, second, and third generation enzyme immunoassays for the diagnosis of HTLV-1/2 infection in ''at-risk'' individuals from Sao Paulo, Brazil
【24h】

Comparison of signal-to-cutoff values in first, second, and third generation enzyme immunoassays for the diagnosis of HTLV-1/2 infection in ''at-risk'' individuals from Sao Paulo, Brazil

机译:比较巴西圣保罗“高危”人群中第一代,第二代和第三代酶免疫测定中HTLV-1 / 2感染的信噪比值

获取原文
获取原文并翻译 | 示例
           

摘要

Data obtained during routine diagnosis of human T-cell lymphotropic virus type 1 (HTLV-1) and 2 (HTLV-2) in ''at-risk'' individuals from Sao Paulo, Brazil using signal-to-cutoff (S/C) values obtained by first, second, and third generation enzyme immunoassay (EIA) kits, were compared. The highest S/C values were obtained with third generation EIA kits, but no correlation was detected between these values and specific antibody reactivity to HTLV-1, HTLV-2, or untyped HTLV (p=0.302). In addition, use of these third generation kits resulted in HTLV-1/2 false-positive samples. In contrast, first and second generation EIA kits showed high specificity, and the second generation EIA kits showed the highest efficiency, despite lower S/C values. Using first and second generation EIA kits, significant differences in specific antibody detection of HTLV-1, relative to HTLV-2 (p=0.019 for first generation and p<0.001 for second generation EIA kits) and relative to untyped HTLV (p=0.025 for first generation EIA kits), were observed. These results were explained by the composition and format of the assays. In addition, using receiver operating characteristics (ROC) analysis, a slight adjustment in cutoff values for third generation EIA kits improved their specificities and should be used when HTLV ''at-risk'' populations from this geographic area are to be evaluated.
机译:在巴西圣保罗的“高危”人群中,常规常规诊断使用信号截止值对人类T细胞淋巴病毒1型(HTLV-1)和2型(HTLV-2)进行诊断时获得的数据比较第一,第二和第三代酶免疫分析(EIA)试剂盒获得的值。使用第三代EIA试剂盒可获得最高的S / C值,但在这些值与对HTLV-1,HTLV-2或未分型HTLV的特异性抗体反应性之间未检测到相关性(p = 0.302)。此外,使用这些第三代试剂盒会产生HTLV-1 / 2假阳性样品。相比之下,尽管S / C值较低,但第一代和第二代EIA试剂盒显示出高特异性,第二代EIA试剂盒显示出最高效率。使用第一代和第二代EIA试剂盒,相对于HTLV-2(第一代p = 0.019,第二代EIA试剂盒p <0.001)和相对于未分型HTLV(p = 0.025),HTLV-1特异性抗体检测有显着差异对于第一代EIA试剂盒)。这些结果由测定的组成和形式解释。此外,使用接收器工作特性(ROC)分析,第三代EIA试剂盒的临界值略有调整,提高了其特异性,应在评估来自该地区的HTLV“高危”人群时使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号