摘要

The experimental friction factor and Nusselt number data for laminar flow through a circular duct having wire coil inserts and fitted with center-cleared twisted tape have been presented. Predictive fiction factor and Nusselt number correlations have also been presented. The thermohydraulic performance has been evaluated. The major findings of this experimental investigation are the center-cleared twisted tapes in combination with wire coil inserts perform better than the individual enhancement technique acting alone for laminar flow through a circular duct up to a certain amount of center-clearance.
机译:已经给出了层流通过具有导线线圈插入件并装有中心清除扭曲带的圆形管道的层流的实验摩擦因数和努塞尔数数据。还提出了预测性小说因子和Nusselt数的相关性。已经评估了热工液压性能。该实验研究的主要发现是,与钢绞线插入件组合使用的中心清除扭绞带的性能优于单独增强技术,该技术单独作用于通过圆形管道的层流直至达到一定程度的中心间隙。