...
首页> 外文期刊>Clinical oral investigations >Influence of calcium hydroxide dressing and acid etching on the push-out bond strengths of three luting resins to root canal dentin
【24h】

Influence of calcium hydroxide dressing and acid etching on the push-out bond strengths of three luting resins to root canal dentin

机译:氢氧化钙敷料和酸蚀对三种树脂对根管牙本质推出强度的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: This study aims to investigate the effects of calcium hydroxide (Ca(OH)2) dressing in root canals and the effects of subsequent acid etching on the adhesion of luting resins to root canals. Materials and methods: Root specimens were prepared from extracted human permanent molars. Specimen canals were (1) filled with etch-and-rinse (Nexus? third generation (NX3)) and two self-adhesive (RelyX Unicem, Maxcem Elite) luting resins, respectively; (2) dressed with Ca(OH)2 before Ca(OH)2 removal and luting resin filling; (3) dressed with Ca(OH)2 before Ca(OH)2 removal and post-cementation; or (4) treated as described in item (2) except that the canals were further etched with phosphoric acid before luting resin filling. Push-out bond strengths were measured and analyzed using one-way analysis of variance, and Fisher's multiple comparison tests provided a follow-up comparison among these four canal treatments. Attenuated total reflectance-Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) were used to analyze the specimen surfaces. Results: Ca(OH)2 dressing adversely affected the bond strengths to canal dentin of the three luting resins tested. Acid etching did not increase the bond strengths. Infrared analysis revealed that Ca(OH)2 dressing caused no structural changes on the dentin surface. XPS and SEM analyses revealed Ca(OH)2 remnants as the ultimate chemical cause leading to the decrease in bond strength. Conclusions: The bond strength of luting resin to dentin was affected by Ca(OH)2 dressing. Acid etching treatment could not increase the bond strength. Clinical relevance: Adhesion of the fiber post to the root canal wall may be compromised after Ca(OH)2 dressing. An effective method for complete removal of Ca(OH)2 dressing or increase of bond strength for luting resin needs to be developed.
机译:目的:本研究旨在研究氢氧化钙(Ca(OH)2)敷料在根管中的作用,以及随后的酸蚀处理对浸润树脂对根管粘附的影响。材料和方法:根标本是从提取的人类永久性磨牙制备的。样品管(1)分别填充蚀刻和冲洗液(Nexus?第三代(NX3))和两种自粘树脂(RelyX Unicem,Maxcem Elite)。 (2)在去除Ca(OH)2并充填树脂之前,用Ca(OH)2包扎; (3)在去除Ca(OH)2并进行胶结后,先用Ca(OH)2包扎;或(4)按(2)所述进行处理,不同的是在将树脂充填之前,用磷酸进一步腐蚀运河。使用单向方差分析来测量和分析推顶粘结强度,Fisher的多重比较测试对这四种运河治疗方法进行了后续比较。使用衰减全反射傅里叶变换红外光谱,X射线光电子能谱(XPS)和扫描电子显微镜(SEM)来分析样品表面。结果:Ca(OH)2敷料不利地影响了三种测试树脂与牙本质的粘结强度。酸蚀刻并没有增加粘结强度。红外分析表明,Ca(OH)2敷料在牙本质表面未引起结构变化。 XPS和SEM分析表明,Ca(OH)2残留物是导致键强度降低的最终化学原因。结论:Ca(OH)2敷料会影响树脂与牙本质的粘结强度。酸蚀刻处理不能增加粘结强度。临床相关性:Ca(OH)2敷料后,纤维桩对根管壁的粘附力可能会受损。需要开发一种完全去除Ca(OH)2敷料或增加用于粘接树脂的粘结强度的有效方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号