PURPOSE: To evaluate the likelihood of successful retrieval of the Gunther Tulip vena cava filter after various implant durations (up to 494 days). MATERIALS AND METHODS: Retrievable Gunther Tulip filters were placed in 554 patients. All patients satisfied requirements for filter placement; the primary indication for placement was specified for 394 patients (71%), as follows: unspecified trauma (n = 164), bariatric procedures (n = 128), orthopedic procedures (n = 36), and other (n = 66). Filter tilt and vena cava injury were assessed at implantation. Filters were not repositioned after placement. At retrieval, filter orientation, vena cava injury, other device-related incidents, and the degree of difficulty associated with retrieval were reported. RESULTS: Filter retrieval was attempted in 275 patients and successful in 248 (90.2%). The mean filter indwell time was 58.9 days (range, 3-494 days). Unsuccessful retrievals (n = 27) were attributed primarily to improper hook orientation (n = 10) or excessive tissue in-growth at the filter legs (n = 16). Of the remaining 279 patients, 223 withdrew from the study, 41 were associated with a decision to keep the filter as a permanent device, 13 died for reasons unrelated to the study, and two had no reported endpoint data. A Kaplan-Meier product-limit survival estimate revealed that the probability of successful device retrieval remained greater than 94% at 12 weeks and greater than 67% at 26 weeks. CONCLUSIONS: This study contributes to the body of clinical data related to retrievable filters, demonstrating reliable retrieval rates at 12 weeks, with successful retrievals up to 17 months after implantation.
机译:目的:评估在各种植入时间(长达494天)后成功取回Gunther Tulip腔静脉滤器的可能性。材料与方法:将可回收的Gunther Tulip过滤器置于554例患者中。所有患者均满足过滤器放置的要求;对394名患者(71%)指定了放置的主要指征,如下:未明确的创伤(n = 164),减肥手术(n = 128),整形外科手术(n = 36)和其他(n = 66)。植入时评估滤器倾斜和腔静脉损伤。放置后未重新放置过滤器。在取回时,报告了滤器定位,腔静脉损伤,其他与设备有关的事件以及与取回相关的困难程度。结果:275例患者尝试进行滤器取回,248例成功(90.2%)。平均过滤器留置时间为58.9天(范围3-494天)。取回失败(n = 27)主要归因于钩子方向不正确(n = 10)或过滤器支腿处组织过度生长(n = 16)。在其余的279名患者中,有223名退出了研究,其中41名与决定将过滤器保留为永久性装置相关,13名因与研究无关的原因死亡,还有2名没有报告终点数据。 Kaplan-Meier产品极限生存估计表明,成功取出器械的概率在12周时仍大于94%,在26周时仍大于67%。结论:这项研究有助于收集与可取回过滤器有关的临床数据,证明了在12周内可靠的回收率,在植入后长达17个月的成功回收率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号