首页> 外文期刊>Journal of Veterinary Internal Medicine >Collection of peripheral blood CD34+ progenitor cells from healthy dogs and dogs diagnosed with lymphoproliferative diseases using a Baxter-Fenwal CS-3000 Plus blood cell separator.
【24h】

Collection of peripheral blood CD34+ progenitor cells from healthy dogs and dogs diagnosed with lymphoproliferative diseases using a Baxter-Fenwal CS-3000 Plus blood cell separator.

机译:使用Baxter-Fenwal CS-3000 Plus 血细胞分离器从健康犬和被诊断患有淋巴增生性疾病的犬中收集外周血CD34 +祖细胞。

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Canine peripheral blood mononuclear cell (PBMC) apheresis using a Baxter-Fenwal CS-3000 Plus automated blood cell separator has not been reported. Objective: To determine the feasibility and safety of using a CS-3000 Plus blood cell separator with a small volume separation container holder (SVSCH) and small volume collection chamber (SVCC) to harvest canine PBMCs from dogs weighing <50 kg. Animals: Eight healthy mongrel dogs and 11 client-owned dogs in clinical remission for lymphoproliferative diseases (LPD). Methods: In this prospective study, aphereses were performed using a Baxter-Fenwal CS-3000 Plus blood cell separator, with or without recombinant human granulocyte colony-stimulating factor (rhG-CSF) treatment. Results: Aphereses from 6 healthy dogs given rhG-CSF yielded an average of 1.1x107+or-8.2x106 CD34+ cells/kg. Aphereses from LPD dogs given rhG-CSF yielded an average of 5.4x106+or-3.25x106 CD34+ cells/kg (P=.17). Higher hematocrit in both groups of dogs receiving rhG-CSF correlated with an increased number of CD34+ cells/kg harvested (healthy, P=.04; LPD, P=.05). Apheresis was well tolerated by all dogs. Conclusions and Clinical Importance: Canine PBMC apheresis using the Baxter-Fenwal CS-3000 Plus cell separator with an SVSCH and SVCC is a feasible and safe option for harvesting an adequate number of CD34+ peripheral blood progenitor cells from dogs weighing >=17 kg for hematopoietic cell transplantation.Digital Object Identifier http://dx.doi.org/10.1111/j.1939-1676.2011.00827.x
机译:背景:尚未报道使用Baxter-Fenwal CS-3000 Plus 自动血细胞分离器进行犬外周血单核细胞(PBMC)血液采血。目的:确定使用带有小体积分离容器支架(SVSCH)和小体积收集室(SVCC)的CS-3000 Plus 血细胞分离器从称重犬中收集犬PBMC的可行性和安全性<50公斤动物:八只健康的杂种狗和十一只客户拥有的狗因淋巴增生性疾病(LPD)临床缓解。方法:在这项前瞻性研究中,使用Baxter-Fenwal CS-3000 Plus 血细胞分离器对单眼动物进行了分离或无重组人粒细胞集落刺激因子(rhG-CSF)处理。结果:接受rhG-CSF的6只健康犬的平均产生的CD34 +细胞为1.1x10 7 +或-8.2x10 6 CD34 +细胞/ kg。给予rhG-CSF的LPD狗的平均产生CD34 +细胞/ kg的平均值为5.4x10 6 +或-3.25x10 6 / kg( P =。 17)。两组接受rhG-CSF的狗的血细胞比容较高均与每公斤收获的CD34 +细胞数量增加相关(健康, P =。04; LPD, P =。05 )。所有狗都对耐受性良好。结论和临床意义:使用带有SVSCH和SVCC的Baxter-Fenwal CS-3000 Plus 细胞分离器进行犬PBMC血液分离术是从狗中收集足够数量的CD34 +外周血祖细胞的可行且安全的选择重量大于等于17千克的造血细胞移植。数字对象标识符http://dx.doi.org/10.1111/j.1939-1676.2011.00827.x

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号