...
首页> 外文期刊>Journal of Veterinary Diagnostic Investigation >Analytical validation of an immunoassay for the quantification of N-terminal pro-B-type natriuretic peptide in feline blood
【24h】

Analytical validation of an immunoassay for the quantification of N-terminal pro-B-type natriuretic peptide in feline blood

机译:定量分析猫血中N端前B型利钠尿肽的免疫分析方法的验证

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The measurement of N-terminal pro-B-type natriuretic peptide (NT-proBNP), a biomarker for heart stress detectable in blood, has been shown to have clinical utility in cats with heart disease. A second-generation feline enzyme-linked immunosorbent assay (Cardiopet (R) proBNP, IDEXX Laboratories Inc., Westbrook, Maine) was developed to measure NT-proBNP in routine feline plasma or serum samples with improved analyte stability. Results of the analytical validation for the second-generation assay are presented. Analytic sensitivity was 10 pmol/l. Accuracy of 103.5% was determined via serial dilutions of 6 plasma samples. Coefficients of variation for intra-assay, interassay, and total precision were in the ranges of 1.6-6.3%, 4.3-8.8%, and 10.1-15.1%, respectively. Repeatability across 2 lots for both serum and plasma had an average coefficient of determination (r(2)) of 0.99 and slope of 1.11. Stability of the analyte was found to be high. In serum samples held at 4 degrees C for 24-72 hr, the mean percent recovery from time zero was 99%. In serum samples held at 25 degrees C for 24 hr, the mean percent recovery from time zero was 91.9%, and for 48 hr, 85.6%. A method comparison of the first- and second-generation assays with a clinically characterized population of cats revealed no difference in the tests' ability to differentiate levels of NT-proBNP between normal cats and cats with occult cardiomyopathy (P 0.001). Results from our study validate that the second-generation feline Cardiopet proBNP assay can measure NT-proBNP in routine feline plasma and serum samples with accuracy and precision.
机译:N末端前B型利钠尿肽(NT-proBNP)(一种可在血液中检测到的心脏压力的生物标记物)的测量已显示在患有心脏病的猫中具有临床用途。开发了第二代猫酶联免疫吸附测定法(Cardiopet ProBNP,IDEXX Laboratories Inc.,缅因州韦斯特布鲁克),以测定常规猫血浆或血清样品中的NT-proBNP,并提高了分析物的稳定性。给出了第二代分析的分析验证结果。分析灵敏度为10 pmol / l。通过连续稀释6个血浆样品确定103.5%的准确性。批内,批间和总精密度的变异系数分别在1.6-6.3%,4.3-8.8%和10.1-15.1%的范围内。血清和血浆两批次的重复性平均测定系数(r(2))为0.99,斜率为1.11。发现分析物的稳定性高。在4摄氏度下保持24-72小时的血清样品中,从零时开始的平均回收百分比为99%。在25摄氏度下保持24小时的血清样品中,从零时间开始的平均回收百分比为91.9%,而在48小时内的回收率为85.6%。对第一代和第二代检测方法与临床特征的猫种群进行的方法比较显示,正常猫和隐匿性心肌病猫之间的区分NT-proBNP水平的能力无差异(P <0.001)。我们的研究结果证实,第二代猫的Cardiopet proBNP检测可以准确,准确地测量常规猫血浆和血清样品中的NT-proBNP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号