...
首页> 外文期刊>Journal of thrombosis and haemostasis: JTH >CD146-based immunomagnetic enrichment followed by multiparameter flow cytometry: a new approach to counting circulating endothelial cells.
【24h】

CD146-based immunomagnetic enrichment followed by multiparameter flow cytometry: a new approach to counting circulating endothelial cells.

机译:基于CD146的免疫磁富集,然后进行多参数流式细胞术:一种计数循环内皮细胞的新方法。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Circulating endothelial cells (CECs) have emerged as non-invasive biomarkers of vascular dysfunction. The most widely used method for their detection is CD146-based immunomagnetic separation (IMS). Although this approach has provided consensus values in both normal and pathologic situations, it remains tedious and requires a trained operator. Objectives: Our objective was to evaluate a new hybrid assay for CEC measurement using a combination of pre-enrichment of CD146+ circulating cells and multiparametric flow cytometry measurement (FCM). PATIENTS AND METHODS: CECs were determined in peripheral blood from 20 healthy volunteers, 12 patients undergoing coronary angioplasty, and 30 renal transplant recipients, and blood spiked with cultured endothelial cells. CD146+ cells were isolated using CD146-coated magnetic nanoparticles and labeled using CD45-fluorescein isothiocyanate and CD146-PE or isotype control antibody and propidium iodide before FCM. The same samples were also processed using CD146-based immunomagnetic separation as the reference method. RESULTS: The hybrid assay detected CECs, identified as CD45(dim)/CD146(bright)/propidium iodide(+), with high size-related scatter characteristics, and clearly discriminated these from CD45(bright)/CD146(dim) activated T lymphocytes. The method demonstrated both high recovery efficiency and good reproducibility. Both IMS and the hybrid assay similarly identified increased CEC levels in patients undergoing coronary angioplasty and renal transplantation, when compared to healthy controls. In patients, CEC values from these two methods were of the same order of magnitude and highly correlated. Bland-Altman analysis revealed poor statistical agreement between methods, flerrofluid-FCM providing higher values than IMS. CONCLUSION: This new hybrid FCM assay constitutes an accurate alternative to visual counting of CECs following CD146-based IMS.
机译:背景:循环内皮细胞(CEC)已经成为血管功能障碍的非侵入性生物标志物。检测它们最广泛使用的方法是基于CD146的免疫磁分离(IMS)。尽管这种方法在正常和病理情况下均提供了共识性价值,但它仍然很繁琐,并且需要经过培训的操作人员。目的:我们的目标是评估CD146 +循环细胞的预富集和多参数流式细胞术(FCM)的组合,以用于CEC测量的新型混合分析。患者和方法:在20名健康志愿者,12例接受冠状动脉成形术的患者和30例肾移植受者的外周血中,以及加有培养的内皮细胞的血液中测定CEC。使用FCD之前,用涂有CD146的磁性纳米颗粒分离CD146 +细胞,并用CD45-异硫氰酸荧光素和CD146-PE或同种型对照抗体和碘化丙啶标记。还使用基于CD146的免疫磁分离作为参考方法处理了相同的样品。结果:混合测定法检测到具有高尺寸相关散射特征的CECs,鉴定为CD45(dim)/ CD146(bright)/碘化丙啶(+),并将其与CD45(bright)/ CD146(dim)活化的T区别开来。淋巴细胞。该方法具有较高的回收效率和良好的重现性。与健康对照相比,IMS和混合试验均相似地确定了接受冠状动脉成形术和肾移植的患者CEC水平升高。在患者中,这两种方法的CEC值处于同一数量级并且高度相关。 Bland-Altman分析显示方法之间的统计一致性较差,而氟流体-FCM提供的值高于IMS。结论:这种新的混合FCM分析方法是基于CD146的IMS后CEC视觉计数的准确替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号