High-order coreal wavefront analysis was performed in a population of 60 myopic eyes that underwent photo-refractive keratectomy. Corneal aberration data over 3, 5, and 7 mm pupils were collected for up to three years after surgery. The optical performance of the anterior cornea was characterized by estimation of the modulation transfer function (MTF) and the point-spread function. The high-order corneal wavefront aberrations were shown to stabilize one year after surgery. Over photopic pupils, after an early slight increase, corneal RMS-high-order aberrations (HOA) tended to decrease toward preoperative values. On the other hand, over mid- and large-pupil sizes, corneal HOA significantly increased compared with the preoperative state, while the optical performance of the cornea was diminished. The MTF ratio showed a distinct decline in the optical quality of postoperative corneas at low and middle spatial frequencies over larger pupils in the range between 6 and 19 c/deg, especially for deeper ablations.
机译:在接受光折射角膜切除术的60只近视眼人群中进行了高阶核心波前分析。手术后长达三年的3、5和7 mm瞳孔的角膜像差数据被收集。通过估计调制传递函数(MTF)和点扩展函数来表征前角膜的光学性能。手术后一年,高阶角膜波前像差稳定下来。在明视瞳孔上,在早期略微增加之后,角膜RMS高阶像差(HOA)趋于朝术前值降低。另一方面,在中,大瞳孔尺寸下,与术前相比,角膜HOA显着增加,而角膜的光学性能却下降。 MTF比值显示在6至19 c / deg范围内的较大瞳孔中,低和中空频率下术后角膜的光学质量明显下降,尤其是对于较深的消融术。