首页> 外文期刊>Journal of synchrotron radiation >Feasibility study of propagation-based phasecontrast X-ray lung imaging on the Imaging and Medical beamline at the Australian Synchrotron
【24h】

Feasibility study of propagation-based phasecontrast X-ray lung imaging on the Imaging and Medical beamline at the Australian Synchrotron

机译:在澳大利亚同步加速器的成像和医学射线线上进行基于传播的相衬X射线肺部成像的可行性研究

获取原文
获取原文并翻译 | 示例

摘要

Propagation-based phase-contrast X-ray imaging (PB-PCXI) using synchrotron radiation has achieved high-resolution imaging of the lungs of small animals both in real time and in vivo. Current studies are applying such imaging techniques to lung disease models to aid in diagnosis and treatment development. At the Australian Synchrotron, the Imaging and Medical beamline (IMBL) is well equipped for PB-PCXI, combining high flux and coherence with a beam size sufficient to image large animals, such as sheep, due to a wiggler source and source-to-sample distances of over 137 m. This study aimed to measure the capabilities of PB-PCXI on IMBL for imaging small animal lungs to study lung disease. The feasibility of combining this technique with computed tomography for three-dimensional imaging and X-ray velocimetry for studies of airflow and non-invasive lung function testing was also investigated. Detailed analysis of the role of the effective source size and sample-to-detector distance on lung image contrast was undertaken as well as phase retrieval for sample volume analysis. Results showed that PB-PCXI of lung phantoms and mouse lungs produced high-contrast images, with successful computed tomography and velocimetry also being carried out, suggesting that live animal lung imaging will also be feasible at the IMBL.
机译:使用同步加速器辐射的基于传播的相衬X射线成像(PB-PCXI)可以实时和体内获得小动物肺部的高分辨率成像。当前的研究正在将这种成像技术应用于肺部疾病模型,以帮助诊断和治疗开发。在澳大利亚同步加速器上,成像和医学光束线(IMBL)装备齐全,可用于PB-PCXI,结合了高通量和相干性以及光束大小,该光束大小足以使大型动物(例如绵羊)成像,这是由于摆动源和光源到光源之间的关系。采样距离超过137 m。这项研究旨在测量IMBL上的PB-PCXI对小动物肺部成像以研究肺部疾病的能力。还研究了将该技术与计算机断层摄影相结合进行三维成像和X射线测速仪用于研究气流和无创肺功能测试的可行性。进行了有效源尺寸和样品到检测器距离对肺图像对比度的作用的详细分析,以及用于样品量分析的相位检索。结果表明,肺部幻像和小鼠肺部的PB-PCXI产生了高对比度的图像,并且还成功进行了计算机断层扫描和测速,这表明在IMBL上进行活体肺部成像也将是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号