首页> 外文期刊>Journal of the Meteorological Society of Japan >Comparison of meisei RS2-91 rawinsondes and Vaisala RS92-SGp radiosondes at Tateno for the data continuity for climatic data analysis
【24h】

Comparison of meisei RS2-91 rawinsondes and Vaisala RS92-SGp radiosondes at Tateno for the data continuity for climatic data analysis

机译:在Tateno比较Meisei RS2-91原始探空仪和Vaisala RS92-SGp探空仪在气候数据分析方面的数据连续性

获取原文
获取原文并翻译 | 示例
           

摘要

Observation instruments are commonly upgraded because of technological advances and the convenience of the observation agency. However, great care is necessary when changing instruments to ensure data continuity for climatic data analysis. The Tateno upper-air observation station of the Japan Meteorological Agency replaced the Meisei RS2-91 type rawinsondes with Vaisala RS92-SGP type GPSsondes in December 2009. We carried out a total of 115 simultaneous dual launches for four seasons to investigate any differences in performance. The simultaneous sensor comparison results showed that Vaisala RS92-SGP temperature was 0.1-0.4K higher than Meisei RS2-91 temperature above the 100 hPa layer in night time observations; and that Meisei RS2-91 temperature was ~0.1K higher above the 30 hPa layer in day time observations. Vaisala RS92-SGP relative humidity was ~5% lower, particularly under humid conditions and in autumn. Vaisala RS92-SGP pressure was ~0.5 hPa higher in the stratosphere. We also made pressure-level comparisons for temperature and relative humidity. Furthermore, comparison results are shown for precipitable water vapor measurements taken with a collocated GPS receiver for a sensitivity analysis on the number of dual soundings and for a reanalysis of upper-air temperature trends for 1956-2010, taking the three instrumental change events into consideration.
机译:由于技术的进步和观察机构的便利,通常对观察仪器进行升级。但是,在更换仪器时必须格外小心,以确保气候数据分析的数据连续性。日本气象厅的立野高空观测站于2009年12月用维萨拉RS92-SGP型GPS探空仪取代了Meisei RS2-91型生皮探空仪。我们总共进行了115次双发同时发射,历时四个季节,以研究性能上的差异。同时进行的传感器比较结果表明,在夜间观测中,维萨拉RS92-SGP温度比100 hPa层以上的Meisei RS2-91温度高0.1-0.4K。在白天的观测中,Meisei RS2-91温度比30 hPa层高约0.1K。维萨拉RS92-SGP的相对湿度降低了5%,尤其是在潮湿的条件下和秋天。在平流层中,维萨拉RS92-SGP压力高约0.5 hPa。我们还对温度和相对湿度进行了压力水平比较。此外,还显示了比较结果,其中显示了并置GPS接收器进行的可降水量水汽测量结果的敏感性,分析了两次探测的数量并重新分析了1956-2010年的高空温度趋势,同时考虑了三个仪器变化事件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号