首页> 外文期刊>Journal of the Institution of Engineers (India). Mechanical Engineering Division >Performance of an Inclined Tube of Open Thermosiphon - an Experimental Study
【24h】

Performance of an Inclined Tube of Open Thermosiphon - an Experimental Study

机译:开放式热虹吸管倾斜管的性能-实验研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this paper, rate of thermally induced flow and heat transfer in an inclined tube of open thermosiphon has been experimentally obtained under uniform heat flux conditions. The test section was a copper tube of 0.022 m internal diameter uniformly heated over a length of 2.13 m. Effects of heat flux and tube inclinations on heat transfer coefficient of water along the test section, were studied to evaluate the performance of an open -loop, inclined tube thermosiphon experimentally. The data have been presented graphically and discussed. Correlations for predicting the average heat transfer coefficient and mass flow rate are proposed.
机译:在本文中,已经在均匀的热通量条件下通过实验获得了开放式热虹吸管的倾斜管中的热诱导流率和热传递率。测试部分是内径为0.022 m的铜管,在2.13 m的长度上均匀加热。研究了热通量和管子倾斜度对水沿测试部分的传热系数的影响,以实验方式评估开环,倾斜管子热虹吸管的性能。数据已以图形方式显示和讨论。提出了用于预测平均传热系数和质量流量的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号