首页> 外文期刊>Journal of the Chemical Society of Pakistan >Flow Injection Spectrophotometric Determination of Total Iron in Fresh Waters using 1,10-Phenanthroline Reagent
【24h】

Flow Injection Spectrophotometric Determination of Total Iron in Fresh Waters using 1,10-Phenanthroline Reagent

机译:1,10-菲咯啉试剂流动注射分光光度法测定淡水中总铁

获取原文
获取原文并翻译 | 示例
           

摘要

A simple flow injection method is reported for the determination of total iron in fresh waters based on spectrophotometric detection of reddish orange iron (II)-1,10-phenanthroline complex measured at wavelength 510 nm. The system permits high throughput of 120 samples per hour. A linear calibration (r~2 = 0.9981) graph was obtained over the concentration range 0.2-1.0 mg L~(-1) with relative standard deviation (n = 4) 0.6-1.0 %. The limit of detection (3σ blank) was 0.01 mg L~(-1). The proposed method has been applied successfully for the determination of iron in fresh water samples and the results obtained (0.04 ± 0.003-0.09 ± 0.01 mg L~(-1)) were in reasonable agreement with the results obtained using a spectrophotometric method (0.05±0.008-0.1±0.005 mg L~(-1)) as the reference method.
机译:根据分光光度法检测在510 nm波长处测得的红橙色铁(II)-1,10-菲咯啉络合物,报告了一种简单的流动注射方法,用于测定淡水中的总铁。该系统每小时可处理120个样品。在0.2-1.0 mg L〜(-1)的浓度范围内获得线性校正(r〜2 = 0.9981)图,相对标准偏差(n = 4)为0.6-1.0%。检测限(3σ空白)为0.01 mg L〜(-1)。所提出的方法已成功用于饮用水中铁的测定,所得结果(0.04±0.003-0.09±0.01 mg L〜(-1))与分光光度法测定的结果(0.05以±0.008-0.1±0.005 mg L〜(-1))作为参考方法。