A rapid and simple method was developed for screening polychlorinated biphenyls in transformer oil. The method is based on liquid-liquid extraction in methanol and subsequent direct gas chromatography-mass spectrometric determination. The extent of methanol polarity allows to extract the PCBs, co-extracting a minimum amount of the apolar oil components, thus avoiding the time-consuming steps involving in sample preparation. Since the regulation established internationally for wastes containing PCBs is 50 mg kg(-1), the method rapidly determines whether the transformer oil is PCBs-contaminated or not. In order to reach the best conditions for extraction a multivariate optimization was carried out considering two significant variables: volume of methanol and extraction time. Under optimum conditions, recoveries of Aroclor 1256 and Aroclor 1260 were between 80 and 100%, and precision, expressed as relative standard deviation, was from 2 to 4%. The method was applied to real samples polluted with PCBs.
机译:开发了一种快速简便的方法来筛选变压器油中的多氯联苯。该方法基于在甲醇中的液-液萃取和随后的直接气相色谱-质谱法测定。甲醇极性的程度允许提取PCB,共提取最少量的非极性油组分,从而避免了样品制备中耗时的步骤。由于国际上针对含PCB的废物制定的法规为50 mg kg(-1),因此该方法可以快速确定变压器油是否受PCBs污染。为了达到最佳提取条件,考虑了两个重要变量进行了多变量优化:甲醇量和提取时间。在最佳条件下,Aroclor 1256和Aroclor 1260的回收率在80%至100%之间,用相对标准偏差表示的精度为2%至4%。该方法适用于被PCB污染的真实样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号