This work describes the application of potentiometric stripping analysis (PSA) at mercury film electrodes for zinc determination in coconut water. A sample ultrasound-assisted treatment was developed and optimised for the total zinc determination by PSA. One milliliter of sample was treated with 2 mL of 1:1 (v/v) concentrated HCl and H2O2 (30% m/v) mixture in closed (4 mL) vessels under sonication (in ultrasonic bath), followed by a thermal step (in a boiling bath, for 15 min). This methodology was optimised for total zinc determination and was validated by graphite furnace atomic absorption spectrometry (GFAAS) analysis utilizing the sample without any treatment. The limit of detection obtained by the proposed PSA method was 1.35 g L-1 (applying 45 s of preconcentration). Attempts to evaluate the amount of copper in the same sample show that the content of this metal is lower than the detection limits of both techniques, GFAAS and PSA (0.030 g L-1 after 600 s of preconcentration) at gold film electrodes.
机译:这项工作描述了电位计溶出分析(PSA)在汞膜电极上用于椰子水中锌测定的应用。开发了一种样品超声辅助处理方法,并对PSA测定总锌进行了优化。在封闭的(4 mL)容器中超声处理(在超声波浴中)用2 mL 1:1(v / v)浓HCl和H2O2(30%m / v)混合物处理1毫升样品,然后进行加热步骤(在沸腾浴中,持续15分钟)。该方法针对总锌的测定进行了优化,并通过未经任何处理的样品通过石墨炉原子吸收光谱法(GFAAS)分析进行了验证。通过拟议的PSA方法获得的检出限为1.35 g L-1(施加45 s的预浓缩)。尝试评估同一样品中的铜量表明,该金属的含量低于金膜电极上两种技术(GFAAS和PSA)的检测极限(预浓缩600 s后为0.030 g L-1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号