首页> 外文期刊>Journal of the American Society of Echocardiography: official publication of the American Society of Echocardiography >Effect of through-plane and twisting motion on left ventricular strain calculation: Direct comparison between two-dimensional and three-dimensional speckle-tracking echocardiography
【24h】

Effect of through-plane and twisting motion on left ventricular strain calculation: Direct comparison between two-dimensional and three-dimensional speckle-tracking echocardiography

机译:穿通和扭转运动对左心室应变计算的影响:二维和三维散斑跟踪超声心动图的直接比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background The aim of this study was to investigate the effect of out-of-plane motion on discrepancies in strain measurements between two-dimensional (2D) and three-dimensional (3D) echocardiography. Methods Two-dimensional and 3D data sets were acquired in 54 patients. Using 2D and 3D speckle-tracking software, global circumferential strain (CS) and longitudinal strain (LS) as well as CS and LS at three left ventricular (LV) levels was measured. The effect of through-plane motion was assessed by mitral annular displacement. Results Although a good correlation of global CS was noted between the two methods (r = 0.80, P <.01), mean values of global CS were significantly higher on 3D compared with 2D echocardiography. Correlations of CS and their mean differences were 0.65 and -4.61 at the basal level, 0.76 and -4.17 at the midventricular level, and 0.60 and -2.23 at the apical level, respectively. Correlation of global CS between the two methods was higher in patients who showed mitral annular displacement < 9.4 mm (r = 0.81) compared with those with mitral annular displacement ≥ 9.4 mm (r = 0.61). A good correlation of global LS (r = 0.89, P <.01) was noted, with no significant bias. Correlations of LS and their mean differences were 0.52 and 1.59 at the basal level, 0.89 and -1.17 at the midventricular level, and 0.73 and 1.46 at the apical level, respectively. Correlation of LS between the two methods was higher in patients who showed LV twist < 12.2 (r = 0.94) compared with patients with LV twist ≥ 12.2 (r = 0.68). Conclusions Through-plane motion produced discrepancies in CS measurements, especially at the LV basal level. Larger bias of LS at the basal and apical LV levels compared with the midventricular level between the two methods suggests that LV twisting also affects the calculation of 2D LS.
机译:背景技术这项研究的目的是调查平面外运动对二维(2D)和三维(3D)超声心动图之间的应变测量差异的影响。方法收集54例患者的二维和3D数据集。使用2D和3D散斑跟踪软件,测量了三个左心室(LV)水平的总体圆周应变(CS)和纵向应变(LS)以及CS和LS。通过二尖瓣环移位评估了平面运动的影响。结果尽管两种方法之间的总体CS密切相关(r = 0.80,P <.01),但与2D超声心动图相比,在3D上全局CS的平均值显着更高。 CS的相关性及其平均差异在基础水平分别为0.65和-4.61,在心室中水平分别为0.76和-4.17,在心尖水平分别为0.60和-2.23。二尖瓣环移位<9.4 mm(r = 0.81)的患者与二尖瓣环移位≥9.4 mm(r = 0.61)的患者相比,两种方法之间的整体CS相关性更高。总体LS的相关性很好(r = 0.89,P <.01),没有显着偏差。 LS的相关性及其平均差在基础水平分别为0.52和1.59,在中脑水平分别为0.89和-1.17,在心尖水平分别为0.73和1.46。 LV扭转<12.2(r = 0.94)的患者与LV扭转≥12.2(r = 0.68)的患者相比,两种方法之间的LS相关性更高。结论平面运动在CS测量中产生差异,尤其是在LV基础水平上。与两种方法之间的脑室中部水平相比,LS在基础和根尖LV水平的偏差更大,这表明LV扭曲也影响2D LS的计算。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号